G-<strong>13.mft</strong> totalizer FUNCTION AND OPERATION (TV TOTALIZER)<br />

Set the pulse pause time<br />

To set the G-<strong>13.mft</strong> in the TV totalizer operation to the specific processing<br />

times of the machine, the DIL switches 7 and 8 of the upper switching block<br />

S1 can be used to set four different pulse pause times:<br />

Pulse/pause<br />

20/80 ms S1<br />

50/200 ms S1<br />

100/400 ms S1<br />

200/800 ms S1<br />

Data-manage the residual credit<br />

If, for a sales transaction, an amount of money is inserted in the device which<br />

is greater than the set price, the customer’s residual credit can be datamanaged<br />

in a number of ways:<br />

• Reset residual credit immediately<br />

Residual credit is reset immediately following pulse output<br />

• Retain residual credit<br />

Residual credit can be used for another vend or another customer<br />

• Retain residual credit for two minutes<br />

Residual credit is reset two minutes after the vending operation<br />

Changing the residual credit data-management<br />

National Rejectors, Inc. GmbH, Buxtehude<br />