G-<strong>13.mft</strong> totalizer FUNCTION AND OPERATION (TIMER)<br />
Tokens<br />
Inventory function<br />
Each coin channel can also be assigned a token instead of a coin; this token<br />
is not assigned an arbitrary value but the value of the price (one service/timer<br />
time for one token). Following the acceptance of a token, the customer’s<br />
credit therefore increases by the set price.<br />
Several tokens can be configured.<br />
If the inventory function has been activated, the timer transmits inventory<br />
pulses for every coin inserted via the 2 nd price line (in this case: inventory<br />
signal line). The pulse number per coin equals the multiple of the smallest<br />
coin value set for this coin.<br />
The inventory pulses can be added up using an external counter and serve<br />
the purpose of verifying the cash-box contents.<br />
Activate/deactivate inventory function<br />
Warning signal before time lapse<br />
National Rejectors, Inc. GmbH, Buxtehude<br />
The inventory function and the output of a warning signal can only be<br />
used alternatively und not combined, as the signals are transmitted<br />
using the same line (see section "Warning signal before time lapse"<br />
in this chapter).<br />
At the manufacturer the timer can be set so that it sends a warning signal<br />
via the second price line (here: warning signal line), before the timer time<br />
purchased has elapsed. Thus the customer's attention is drawn to the fact<br />
that he has to insert further coins, if the time is to be run on.<br />
The purchased time determines when the warning signal is transmitted:<br />
Timer purchased Signal ... before time has elapsed<br />
– 59 sec. no signal<br />
1 min. – 9 min. 59 sec. 30 sec.<br />
10 min. – 59 min. 59 sec. 1 min.<br />
1 h – 10 min.<br />
Activate/deactivate warning signal output<br />
The output of a warning signal and the inventory function can only be<br />
used alternatively and not combined, as the signals are transmitted<br />
using the same line (see section "Warning signal before time lapse"<br />
in this chapter).<br />