G-<strong>13.mft</strong> totalizer FUNCTION AND OPERATION (TIMER)<br />

Tokens<br />

Inventory function<br />

Each coin channel can also be assigned a token instead of a coin; this token<br />

is not assigned an arbitrary value but the value of the price (one service/timer<br />

time for one token). Following the acceptance of a token, the customer’s<br />

credit therefore increases by the set price.<br />

Several tokens can be configured.<br />

If the inventory function has been activated, the timer transmits inventory<br />

pulses for every coin inserted via the 2 nd price line (in this case: inventory<br />

signal line). The pulse number per coin equals the multiple of the smallest<br />

coin value set for this coin.<br />

The inventory pulses can be added up using an external counter and serve<br />

the purpose of verifying the cash-box contents.<br />

Activate/deactivate inventory function<br />

Warning signal before time lapse<br />

National Rejectors, Inc. GmbH, Buxtehude<br />

The inventory function and the output of a warning signal can only be<br />

used alternatively und not combined, as the signals are transmitted<br />

using the same line (see section "Warning signal before time lapse"<br />

in this chapter).<br />

At the manufacturer the timer can be set so that it sends a warning signal<br />

via the second price line (here: warning signal line), before the timer time<br />

purchased has elapsed. Thus the customer's attention is drawn to the fact<br />

that he has to insert further coins, if the time is to be run on.<br />

The purchased time determines when the warning signal is transmitted:<br />

Timer purchased Signal ... before time has elapsed<br />

– 59 sec. no signal<br />

1 min. – 9 min. 59 sec. 30 sec.<br />

10 min. – 59 min. 59 sec. 1 min.<br />

1 h – 10 min.<br />

Activate/deactivate warning signal output<br />

The output of a warning signal and the inventory function can only be<br />

used alternatively and not combined, as the signals are transmitted<br />

using the same line (see section "Warning signal before time lapse"<br />

in this chapter).<br />