G-<strong>13.mft</strong> totalizer FUNCTION AND OPERATION (TIMER)<br />

Set the timer time<br />

The timer sells a service over a specific period of time. You can set the time<br />

available to a customer for the credit of the set price as a binary value using<br />

the lower switching block S2:<br />

S2.1...S2.8, S2.10<br />

DIL switch S2.10 defines the unit of time (seconds (ON) or minutes (OFF)).<br />

Example – time unit "minutes"<br />

The timer is to be set to a time of 15 min. A valency of 15 must therefore be set using<br />

the DIL switches.<br />

Valency 1 2 48 16 32 64128<br />

Time = 8 + 4 + 2 + 1 = 15<br />

To set a timer time of 15 min., the DIL switches 1 to 4 of the lower switching block<br />

S2 must be set upward to ON and DIL switch 10 downward (to OFF)!<br />

Example – time unit "seconds"<br />

The timer is to be set to a time of 200 sec. A valency of 200 must therefore be set<br />

using the DIL switches.<br />

Valency 1 2 48 16 32 64128<br />

Time = 128 +64 +8 = 200<br />

To set a timer time of 200 sec., the DIL switches 4, 7, 8 and 10 of the lower<br />

switching block S2 must be set upward to ON!<br />

National Rejectors, Inc. GmbH, Buxtehude<br />

S1<br />

S2<br />

25