Seiberling<br />

The vessel capacity may range from 30L to 16 m 3 or more. A majority of<br />

CIP-cleaned processes areautomatically controlled and the vessel and its dedicated<br />

piping will include air-operated valves to fill (T1V1 and T2V1), empty (T1V2 and<br />

T2V2), supply flush, wash and rinse solutions to the circuit (T1V3 and T2V3), and to<br />

subcircuits such as dip tubes and sample connections. Valves for the vent filter,<br />

sampling, etc., may be manually operated or automated, this decision being made<br />

on the basis of process automation requirements. An outlet valve of adequate size to<br />

accommodate CIP flush, wash and rinse solution flow rates is mandatory and aflat<br />

plate vortex breaker above the outlet opening is highly recommended to minimize<br />

air entrainment and prevent cavitation of any required return pumps. Additional<br />

criteria for CIPable design will follow later in this chapter.<br />

Figure 2isaphoto of typical tank top piping as shown schematically in<br />

Figure 1including avent filter with amanual valve and arupturedisk. The two airoperated<br />

valves upper left control flow from acommon line originating at aTPto<br />

either the inlet, or the spray, orboth (for CIP) and are equivalent to T1V1 and T1V3<br />

on T1 in the figure. Figure 3shows the spray balls to either side behind the manway<br />

rim, and amagnetically driven agitator and permanently installed flat plate vortex<br />

breaker on the bottom. The selection and application of spray devices is described in<br />

chapter 9.<br />

U-Bend Transfer Panels<br />

Multi-port TPs (TP1 and TP2) shown as (3) are generally used to organize<br />

installation and support of product and CIPS/CIPR piping, and facilitate connections<br />

for required production, CIP and SIP operations. The design and application<br />

of TPs is described in depth in chapter 12. TPs require manual operations to<br />

FIGURE 2 This view of amedia prep vessel illustrates the high manway collar and also the rupture<br />

disc, vent filter, and level indicator nozzles that create clean-in-place spray coverage problems.