CIP Distribution Piping Systems 179<br />

FIGURE 3 Portable clean-in-place return pump<br />

mounted on astainless steel dolly.<br />

true and comparable attention must be given to proper gasketing of all openings<br />

except the one in use, to achieve the desired benefits of drawing air only through the<br />

vessel outlet, and hence accomplishing CIP with an essentially empty vessel.<br />

Whereas eductor return flow can be used as asole motivating force for short<br />

CIPR runs involving minimal static head, an eductor-only return flow is most<br />

commonly used in conjunction with gravity return. As an adjunct to gravity return,<br />

the eductor will increase the flow rate achieved by gravity alone.<br />

Eductor-Assisted Pumped Return Flow<br />

Eductor-assisted return used in conjunction with either low- or high-speed return<br />

pumps is extremely reliable and effective. High-speed return pumps, without selfpriming<br />

casings or air relief valves, can be used in combination with small-diameter<br />

FIGURE 4 Fixed base-mounted clean-in-place return<br />

pump.