Data Queue APIs--Categories - FTP Directory Listing - IBM
Data Queue APIs--Categories - FTP Directory Listing - IBM
Data Queue APIs--Categories - FTP Directory Listing - IBM
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Send <strong>Data</strong> <strong>Queue</strong> (QSNDDTAQ) API<br />
❍<br />
Scenario 3<br />
If,<br />
❍<br />
❍<br />
❍<br />
then,<br />
❍<br />
the job continues to reference the original DDM data queue, not the newly created data queue.<br />
a job references a DDM data queue, which starts a DDM target job (DDM conversation) on a<br />
remote system that references a library-specific data queue,<br />
the data queue on the remote system is moved using the Move Object (MOVOBJ) command<br />
or renamed using the Rename Object (RNMOBJ) command, and<br />
on the remote system, a new data queue is created with the same name and library as the data<br />
queue that was renamed or moved,<br />
the DDM target job continues to reference the original data queue on the remote system, not<br />
the newly created data queue, only when the same DDM target job is used for the subsequent<br />
data queue operation. If a new DDM target job is used for the subsequent data queue<br />
operation, then the newly created data queue will be used on the remote system.<br />
Note: For more information on creating DDM data queues and on DDM target jobs, see the<br />
Distributed <strong>Data</strong> Management book.<br />
Length of data<br />
INPUT; PACKED(5,0)<br />
<strong>Data</strong><br />
The number of characters to be sent to the data queue.<br />
Note: An error occurs if the value specified is greater than the length specified by the maximum<br />
length (MAXLEN) parameter on the Create <strong>Data</strong> <strong>Queue</strong> (CRTDTAQ) command.<br />
INPUT; CHAR(*)<br />
The data to be sent to the data queue.<br />
Note: If the length of this field is larger than the length of data parameter, only the number of<br />
characters (beginning from the left) as defined by the length of data parameter are sent to the data<br />
queue. If the length of this variable is smaller than the length of data parameter, unexpected results<br />
can occur.<br />
Optional Parameter Group 1<br />
Length of key data<br />
INPUT; PACKED(3,0)<br />
The number of characters in the key data parameter.<br />
Note: The maximum value is the value that is specified on the KEYLEN parameter on the Create<br />
<strong>Data</strong> <strong>Queue</strong> (CRTDTAQ) command.<br />
Key data<br />
http://infocntr.rchland.ibm.com/pubs/html/as400/v4r5/ic2924/info/apis/qsnddtaq.htm (3 of 5) [10/4/1999 2:32:39 PM]