<strong>AionDS</strong> runtime errors<br />

.........................................................................................................................................................................................................˝..........................................<br />

1359<br />

1-64 <strong>AionDS</strong> <strong>Messages</strong> <strong>and</strong> <strong>Codes</strong><br />

Object referenced in CM function is non-simple <strong>and</strong> can’t be sourced<br />

<strong>AionDS</strong> cannot execute a CM statement for the specified object because the<br />

object is too complex to be displayed on a single screen. The most complex<br />

object <strong>AionDS</strong> can display is a list of records in which all fields have basic<br />

data types.<br />

.........................................................................................................................................................................................................˝..........................................<br />

1360<br />

Class must have an attached display to be sourced<br />

<strong>AionDS</strong> is unable to source values for the class because the class has no<br />

attached display.<br />

.........................................................................................................................................................................................................˝..........................................<br />

1361<br />

Class contains list or set slots; may not be sourced<br />

<strong>AionDS</strong> cannot execute a CM or ASK statement for the specified class<br />

because the class is too complex to be displayed on a single screen. The most<br />

complex class that <strong>AionDS</strong> can display is one in which all slots have basic<br />

data types.<br />

.........................................................................................................................................................................................................˝..........................................<br />

1362<br />

Illegal comparison - types are not compatible<br />

<strong>AionDS</strong> is unable to compare the values of an instance with those of an<br />

instance of another class. The comparison fails because there is a slot in one<br />

class that has the same position as a slot in the other class, but the type<br />

definition for these slots is different. For example, this error occurs if the<br />

third slot of one class has a different type than the third slot of the other class.<br />

.........................................................................................................................................................................................................˝..........................................<br />

1363<br />

Class may not be loaded at this time; FLUSH required<br />

<strong>AionDS</strong> is unable to execute the DBMS(LOAD) statement because instances<br />

are already loaded in memory. The instances in memory may have been<br />

loaded as a result of a DBMS(LOAD) statement, or they may have been<br />

loaded automatically. This error can also occur if <strong>AionDS</strong> has created<br />

instances, <strong>and</strong> executed a DBMS(UPDATE) statement.