<strong>AionDS</strong> runtime errors<br />

.........................................................................................................................................................................................................˝..........................................<br />

1220<br />

1-60 <strong>AionDS</strong> <strong>Messages</strong> <strong>and</strong> <strong>Codes</strong><br />

Graphics subsystem received unexpected OS return code<br />

<strong>AionDS</strong> is unable to display a graph because of an unexpected signal from the<br />

operating system. Check that the driver <strong>and</strong> the DLL are correctly located.<br />

If they are in the proper directories, contact PLATINUM Technical Support<br />

for <strong>AionDS</strong>.<br />

.........................................................................................................................................................................................................˝..........................................<br />

1221<br />

Unable to lock foreground screen<br />

Graphics require the foreground screen. <strong>AionDS</strong> must not be running in the<br />

background when an attempt is made to display a graph.<br />

.........................................................................................................................................................................................................˝..........................................<br />

1320<br />

Class with invalid objects was entered<br />

<strong>AionDS</strong> is unable to ask slot values for the class because the class contains<br />

invalid objects.<br />

.........................................................................................................................................................................................................˝..........................................<br />

1334<br />

Invalid add to processed list/set ignored<br />

<strong>AionDS</strong> is unable to add a value to the list or set because the parameter or<br />

slot has been processed <strong>and</strong> its Value Can Change property is FALSE. Check<br />

the logic to see why a rule or function tries to add a value after the parameter<br />

or slot is processed.<br />

.........................................................................................................................................................................................................˝..........................................<br />

1336<br />

Invalid argument (must be a full parameter reference)<br />

Check to see if the field of a record was specified instead of the entire<br />

parameter.<br />

.........................................................................................................................................................................................................˝..........................................<br />

1337<br />

Invalid argument (must be a VCC parameter)<br />

Check to see if the parameter specified in the argument has the Value Can<br />

Change property set to TRUE.