29.06.2013 Views

AionDS Messages and Codes Guide

AionDS Messages and Codes Guide

AionDS Messages and Codes Guide

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

MAESLOG messages<br />

.........................................................................................................................................................................................................˝..........................................<br />

12501<br />

6-46 <strong>AionDS</strong> <strong>Messages</strong> <strong>and</strong> <strong>Codes</strong><br />

SAESRUID<br />

This log message is issued when the low-level VTAM routines detect an error.<br />

Analyze the error situation using the log message that SAESGET writes to the<br />

MAESLOG prior to this log message. If a true VTAM error occurred (not a<br />

logical error managing the message), MAESSYNA writes a log message to the<br />

MAESLOG.<br />

.........................................................................................................................................................................................................˝..........................................<br />

12502<br />

SAESRUID<br />

When the low-level VTAM receive routine is called, the expected size of the<br />

user input data is passed. This log message indicates that the request unit size<br />

received by SAESGET was greater than the size that SAESRUID expected.<br />

This is a programming error in either ADSFPL, AAESFPL or DCFPL. The<br />

amount of data actually sent must be the same amount that SAESRUID<br />

expects.<br />

.........................................................................................................................................................................................................˝..........................................<br />

12620<br />

SAESSEND<br />

The calling function attempted to receive a message. However, the session<br />

was in SEND mode, so the request was rejected with an error.<br />

.........................................................................................................................................................................................................˝..........................................<br />

13000<br />

MAESNCON<br />

When MAES is unable to resume a consultation because the consultation ID<br />

cannot be found, <strong>AionDS</strong> control blocks are printed. PLATINUM Technical<br />

Support for <strong>AionDS</strong> can use these <strong>AionDS</strong> control blocks to debug the<br />

problem.<br />

.........................................................................................................................................................................................................˝..........................................<br />

13001<br />

MAESNCON<br />

When MAES terminates an existing consultation because a second<br />

consultation start request was received, <strong>AionDS</strong> control blocks are printed.<br />

PLATINUM Technical Support for <strong>AionDS</strong> can use these <strong>AionDS</strong> control<br />

blocks to further analyze the problem.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!