ADSMSW (Message switching function)<br />

ADSMSW (Message switching function)<br />

.........................................................................................................................................................................................................˝..........................................<br />

Introduction<br />

4-2 <strong>AionDS</strong> <strong>Messages</strong> <strong>and</strong> <strong>Codes</strong><br />

The codes described below can be returned by the ADSMSW Program<br />

Interface Routine.<br />

.........................................................................................................................................................................................................˝..........................................<br />

354<br />

Unexpected message type.<br />

The transaction driver received a message from MAES but the message type<br />

was inconsistent with the current state of the transaction driver. Contact<br />

PLATINUM Technical Support for <strong>AionDS</strong>.<br />

.........................................................................................................................................................................................................˝..........................................<br />

368<br />

Invalid program or queue name in the comm<strong>and</strong> string.<br />

(CICS)<br />

The message switch failed because the CICS program or transient data queue<br />

was not found. Correct the name in the comm<strong>and</strong> string.<br />

.........................................................................................................................................................................................................˝..........................................<br />

368<br />

Invalid transaction name in the comm<strong>and</strong> string. (IMS)<br />

One of the following conditions was encountered:<br />

■ The PSB did not have an alternate I/O PCB for the target transaction.<br />

■ The PSB did not have a modifiable PCB.<br />

■ The change call (CHNG) to the modifiable PCB failed.<br />

Correct the PSB to either provide an alternate I/O PCB for the target<br />

transaction, or add a modifiable PCB that the IMS transaction driver can use.<br />

If either of those PCBs exist, be sure that the name of the transaction in the<br />

knowledge base is correct.<br />

.........................................................................................................................................................................................................˝..........................................<br />

1001<br />

The comm<strong>and</strong> string is empty.<br />

Correct the comm<strong>and</strong> string in the <strong>AionDS</strong> Process object that called<br />

ADSMSW.