<strong>AionDS</strong> runtime errors<br />

.........................................................................................................................................................................................................˝..........................................<br />

32803<br />

Unable to update all the modified instances<br />

<strong>AionDS</strong> cannot complete execution of the DBMS(UPDATE) statement<br />

because it encountered a database error for one or more instances. The<br />

instances that were not updated are reported in the <strong>AionDS</strong> consultation<br />

trace, under error 32805.<br />

.........................................................................................................................................................................................................˝..........................................<br />

32804<br />

Data Integrity Check failed<br />

<strong>AionDS</strong> did not update an instance in the database because the current data<br />

for the instance on disk is not the same as when it was first read into <strong>AionDS</strong>.<br />

<strong>AionDS</strong> checked the data because the Data Integrity Check property in the<br />

access method is TRUE.<br />

.........................................................................................................................................................................................................˝..........................................<br />

32805<br />

Problem occurred updating %1<br />

<strong>AionDS</strong> is unable to execute the DBMS(UPDATE) statement for this<br />

instance. The error message displayed immediately after this message, in the<br />

<strong>AionDS</strong> consultation trace, identifies the specific problem.<br />

.........................................................................................................................................................................................................˝..........................................<br />

32806<br />

Access Method not supported by current environment<br />

<strong>AionDS</strong> is unable to access the database or file because the knowledge base<br />

uses an access method that is not available in the operating environment.<br />

.........................................................................................................................................................................................................˝..........................................<br />

32807<br />

Unable to update new instances using QSAM access method<br />

Dynamically created instances cannot be updated using the QSAM access<br />

method with ADI. Only instances that are loaded may be updated using<br />

QSAM.<br />