AionDS Messages and Codes Guide

AionDS Messages and Codes Guide AionDS Messages and Codes Guide

arti.vub.ac.be
from arti.vub.ac.be More from this publisher
29.06.2013 Views

AionDS runtime errors .........................................................................................................................................................................................................˝.......................................... 22560 1-148 AionDS Messages and Codes Top Margin is less than 0 The specified top margin is above the top of the page. Check the Top Margin property and uses of the &TM command. .........................................................................................................................................................................................................˝.......................................... 22561 Bottom Margin is less than 0 The specified bottom margin is below the bottom of the page. Check the Bottom Margin property and uses of the &BM command. .........................................................................................................................................................................................................˝.......................................... 22562 Top Margin + Bottom Margin is greater than or equal to Page Length The specifications of the top and bottom margin allow no room for text. Check the Top Margin, Bottom Margin, and Page Length properties and uses of the &TM and &BM commands. .........................................................................................................................................................................................................˝.......................................... 22563 Right Margin is larger than window width The right margin can be no greater than the width of the window. Check uses of the &RM and &RI commands. .........................................................................................................................................................................................................˝.......................................... 22572 Command not allowed in a &TBL command There is a command used in the &TBL command that is not allowed. Check the &TBL command and any messages that are included in the table by means of the &MSG command or message passing, such as with the &SEND command. .........................................................................................................................................................................................................˝.......................................... 22575 Column is too wide There is column text in a table that exceeds the line length (in a report) or the window width (in other objects). Check the data for the table and other text that appears in the table.

AionDS runtime errors .........................................................................................................................................................................................................˝.......................................... 22576 Real number has too many digits; use exponential notation (%param:width) AionDS cannot substitute a real number value because the number has too many digits in the specified format (%param:width:precision). To correct this, use the %param:width format. The number will then appear in exponential notation. .........................................................................................................................................................................................................˝.......................................... 22578 Command not allowed in the title of a table There is a command used in the title specification of the &TBL command that is not allowed. Check the title and any messages that are included in the title by means of the &MSG command or message passing, such as with the &SEND command. .........................................................................................................................................................................................................˝.......................................... 22581 The table’s title takes more lines than are available per page The longest column title takes more lines than are available on a page. The available lines per page are calculated by subtracting the top margin and the bottom margin from the page length. Check the title and any messages that are included in the title by means of the &MSG command or message passing, such as with the &SEND command. Also check the Top Margin, Bottom Margin, and Page Length properties and uses of the &TM and &BM commands. .........................................................................................................................................................................................................˝.......................................... 22591 Send Up may not be used in a title or footer The &SEND(... UP) or %UP statement is not allowed in a report’s title or footer. Change the text to a regular SEND or another statement. AionDS Runtime Errors 1-149

<strong>AionDS</strong> runtime errors<br />

.........................................................................................................................................................................................................˝..........................................<br />

22576<br />

Real number has too many digits; use exponential notation<br />

(%param:width)<br />

<strong>AionDS</strong> cannot substitute a real number value because the number has too<br />

many digits in the specified format (%param:width:precision). To correct<br />

this, use the %param:width format. The number will then appear in<br />

exponential notation.<br />

.........................................................................................................................................................................................................˝..........................................<br />

22578<br />

Comm<strong>and</strong> not allowed in the title of a table<br />

There is a comm<strong>and</strong> used in the title specification of the &TBL comm<strong>and</strong><br />

that is not allowed. Check the title <strong>and</strong> any messages that are included in the<br />

title by means of the &MSG comm<strong>and</strong> or message passing, such as with the<br />

&SEND comm<strong>and</strong>.<br />

.........................................................................................................................................................................................................˝..........................................<br />

22581<br />

The table’s title takes more lines than are available per page<br />

The longest column title takes more lines than are available on a page. The<br />

available lines per page are calculated by subtracting the top margin <strong>and</strong> the<br />

bottom margin from the page length.<br />

Check the title <strong>and</strong> any messages that are included in the title by means of<br />

the &MSG comm<strong>and</strong> or message passing, such as with the &SEND<br />

comm<strong>and</strong>.<br />

Also check the Top Margin, Bottom Margin, <strong>and</strong> Page Length properties <strong>and</strong><br />

uses of the &TM <strong>and</strong> &BM comm<strong>and</strong>s.<br />

.........................................................................................................................................................................................................˝..........................................<br />

22591<br />

Send Up may not be used in a title or footer<br />

The &SEND(... UP) or %UP statement is not allowed in a report’s title or<br />

footer. Change the text to a regular SEND or another statement.<br />

<strong>AionDS</strong> Runtime Errors 1-149

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!