AionDS runtime errors .........................................................................................................................................................................................................˝.......................................... 21325 1-144 AionDS Messages and Codes Must specify member of the partitioned dataset AionDS is not able to allocate the file specified. The file specification identifies a physical sequential dataset, but the dataset is partitioned. .........................................................................................................................................................................................................˝.......................................... 21326 Dataset has unsupported organization AionDS is not able to allocate the file specified, because the dataset organization is not supported. A partitioned or physical sequential dataset must be specified. .........................................................................................................................................................................................................˝.......................................... 21327 No space in partitioned dataset directory AionDS is not able to save a member of a partitioned dataset because the directory space has been exhausted. Check the number of directory blocks that are allocated for the PDS. .........................................................................................................................................................................................................˝.......................................... 21328 Unexpected CMS file processing error (completion code ‘%5’) An unexpected CMS file processing error occurred. .........................................................................................................................................................................................................˝.......................................... 21330 Disk not accessed AionDS is not able to find a CMS file because the minidisk is not accessed. .........................................................................................................................................................................................................˝.......................................... 21331 Invalid filemode An invalid CMS filemode was specified. Check the file specification. .........................................................................................................................................................................................................˝.......................................... 21332 Unable to open file An unexpected CMS file processing error occurred opening a file.

AionDS runtime errors .........................................................................................................................................................................................................˝.......................................... 21333 Error during file close An unexpected CMS file processing error occurred closing a file. .........................................................................................................................................................................................................˝.......................................... 21334 Error during write to file An unexpected CMS file processing error occurred writing to a file. .........................................................................................................................................................................................................˝.......................................... 21335 Error during read from file An unexpected CMS file processing error occurred reading from a file. .........................................................................................................................................................................................................˝.......................................... 21337 Requested space not available (MVS) AionDS is not able to save a dataset or a member of a partitioned dataset because the volume on which the dataset resides is full. This error will most likely occur when AionDS detects a System Completion Code 4714. .........................................................................................................................................................................................................˝.......................................... 21337 Invalid logical record length (VM) AionDS is not able to access the CMS file because the logical record length is invalid. .........................................................................................................................................................................................................˝.......................................... 21338 Dataset member not found or other error occurred during OPEN AionDS is not able to open a member of a partitioned dataset. This error will most likely occur when AionDS detects a System Completion Code 013. .........................................................................................................................................................................................................˝.......................................... 21339 Dataset is already cataloged (MVS) AionDS is not able to catalog the file with the specified name because it is already cataloged. AionDS Runtime Errors 1-145

<strong>AionDS</strong> runtime errors<br />

.........................................................................................................................................................................................................˝..........................................<br />

21333<br />

Error during file close<br />

An unexpected CMS file processing error occurred closing a file.<br />

.........................................................................................................................................................................................................˝..........................................<br />

21334<br />

Error during write to file<br />

An unexpected CMS file processing error occurred writing to a file.<br />

.........................................................................................................................................................................................................˝..........................................<br />

21335<br />

Error during read from file<br />

An unexpected CMS file processing error occurred reading from a file.<br />

.........................................................................................................................................................................................................˝..........................................<br />

21337<br />

Requested space not available (MVS)<br />

<strong>AionDS</strong> is not able to save a dataset or a member of a partitioned dataset<br />

because the volume on which the dataset resides is full. This error will most<br />

likely occur when <strong>AionDS</strong> detects a System Completion Code 4714.<br />

.........................................................................................................................................................................................................˝..........................................<br />

21337<br />

Invalid logical record length (VM)<br />

<strong>AionDS</strong> is not able to access the CMS file because the logical record length is<br />

invalid.<br />

.........................................................................................................................................................................................................˝..........................................<br />

21338<br />

Dataset member not found or other error occurred during OPEN<br />

<strong>AionDS</strong> is not able to open a member of a partitioned dataset. This error will<br />

most likely occur when <strong>AionDS</strong> detects a System Completion Code 013.<br />

.........................................................................................................................................................................................................˝..........................................<br />

21339<br />

Dataset is already cataloged (MVS)<br />

<strong>AionDS</strong> is not able to catalog the file with the specified name because it is<br />

already cataloged.<br />

<strong>AionDS</strong> Runtime Errors 1-145