AionDS Messages and Codes Guide

AionDS Messages and Codes Guide AionDS Messages and Codes Guide

arti.vub.ac.be
from arti.vub.ac.be More from this publisher
29.06.2013 Views

AionDS runtime errors .........................................................................................................................................................................................................˝.......................................... 20125 1-112 AionDS Messages and Codes Zoned size exceeds 65512 A record definition specifies more than 65,512 bytes for a zoned real number. Check the AionDS system log for more information about the error. Check the record definition. .........................................................................................................................................................................................................˝.......................................... 20126 Fixed size must be 2 or 4 A record definition specifies a fixed real number with an invalid size. Check the AionDS system log for more information about the error. Check the record definition. A fixed real number must be either 2 or 4 bytes. .........................................................................................................................................................................................................˝.......................................... 20127 Real size must be 4 or 8 A record definition specifies a real number with an invalid size. Check the AionDS system log for more information about the error. Check the record definition. A real number must be either 4 or 8 bytes. .........................................................................................................................................................................................................˝.......................................... 20200 20200 File is not open (PC/WIN/OS2/PM/SUN/AIX/VM) Dataset is not open (MVS) The file is not open for I/O operations. Check that an OPENFILE statement has been executed. .........................................................................................................................................................................................................˝.......................................... 20201 Invalid field specified for keyed selection The AionDS record field specified for a VSAM keyed select is invalid. Check the use of the SELECT statement. .........................................................................................................................................................................................................˝.......................................... 20202 Parent file variable is not open An OPENFILE on a DL/I segment failed because the parent segment (file variable) has not been opened. Check that an OPENFILE statement on the parent segment is executed before an OPENFILE on the child segment.

AionDS runtime errors .........................................................................................................................................................................................................˝.......................................... 20203 Invalid field or variable name The DL/I select field value is unknown. .........................................................................................................................................................................................................˝.......................................... 20204 Invalid variable record length; not within AionDS record length The variable record length specified for the KDL PUTREC statement is invalid because it exceeds the AionDS record length. The AionDS record length is computed according to the record definition in the base type of the file parameter. .........................................................................................................................................................................................................˝.......................................... 20300 File not found (PC/WIN/OS2/PM/SUN/AIX) The requested record I/O processing cannot be performed because the file cannot be found. Check for a valid path and filename. .........................................................................................................................................................................................................˝.......................................... 20300 Member specification not allowed (MVS/VM) A member of a partitioned dataset cannot be used for the requested record I/O processing. .........................................................................................................................................................................................................˝.......................................... 20301 Retrieved record with incorrect record length (PC/WIN/OS2/PM/SUN/AIX) The length of the record retrieved is smaller than the associated AionDS record definition. Check that the record definition correctly matches the external data format. .........................................................................................................................................................................................................˝.......................................... 20301 20301 Dataset record length inconsistent with type definition (MVS) File record length inconsistent with type definition (VM) The record length of the file is smaller than the associated AionDS record definition. Check that the record definition correctly matches the external data format. AionDS Runtime Errors 1-113

<strong>AionDS</strong> runtime errors<br />

.........................................................................................................................................................................................................˝..........................................<br />

20203<br />

Invalid field or variable name<br />

The DL/I select field value is unknown.<br />

.........................................................................................................................................................................................................˝..........................................<br />

20204<br />

Invalid variable record length; not within <strong>AionDS</strong> record length<br />

The variable record length specified for the KDL PUTREC statement is<br />

invalid because it exceeds the <strong>AionDS</strong> record length. The <strong>AionDS</strong> record<br />

length is computed according to the record definition in the base type of the<br />

file parameter.<br />

.........................................................................................................................................................................................................˝..........................................<br />

20300<br />

File not found (PC/WIN/OS2/PM/SUN/AIX)<br />

The requested record I/O processing cannot be performed because the file<br />

cannot be found. Check for a valid path <strong>and</strong> filename.<br />

.........................................................................................................................................................................................................˝..........................................<br />

20300<br />

Member specification not allowed (MVS/VM)<br />

A member of a partitioned dataset cannot be used for the requested record<br />

I/O processing.<br />

.........................................................................................................................................................................................................˝..........................................<br />

20301<br />

Retrieved record with incorrect record length<br />

(PC/WIN/OS2/PM/SUN/AIX)<br />

The length of the record retrieved is smaller than the associated <strong>AionDS</strong><br />

record definition. Check that the record definition correctly matches the<br />

external data format.<br />

.........................................................................................................................................................................................................˝..........................................<br />

20301<br />

20301<br />

Dataset record length inconsistent with type definition (MVS)<br />

File record length inconsistent with type definition (VM)<br />

The record length of the file is smaller than the associated <strong>AionDS</strong> record<br />

definition. Check that the record definition correctly matches the external<br />

data format.<br />

<strong>AionDS</strong> Runtime Errors 1-113

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!