AionDS Messages and Codes Guide
AionDS Messages and Codes Guide AionDS Messages and Codes Guide
AionDS runtime errors .........................................................................................................................................................................................................˝.......................................... 20125 1-112 AionDS Messages and Codes Zoned size exceeds 65512 A record definition specifies more than 65,512 bytes for a zoned real number. Check the AionDS system log for more information about the error. Check the record definition. .........................................................................................................................................................................................................˝.......................................... 20126 Fixed size must be 2 or 4 A record definition specifies a fixed real number with an invalid size. Check the AionDS system log for more information about the error. Check the record definition. A fixed real number must be either 2 or 4 bytes. .........................................................................................................................................................................................................˝.......................................... 20127 Real size must be 4 or 8 A record definition specifies a real number with an invalid size. Check the AionDS system log for more information about the error. Check the record definition. A real number must be either 4 or 8 bytes. .........................................................................................................................................................................................................˝.......................................... 20200 20200 File is not open (PC/WIN/OS2/PM/SUN/AIX/VM) Dataset is not open (MVS) The file is not open for I/O operations. Check that an OPENFILE statement has been executed. .........................................................................................................................................................................................................˝.......................................... 20201 Invalid field specified for keyed selection The AionDS record field specified for a VSAM keyed select is invalid. Check the use of the SELECT statement. .........................................................................................................................................................................................................˝.......................................... 20202 Parent file variable is not open An OPENFILE on a DL/I segment failed because the parent segment (file variable) has not been opened. Check that an OPENFILE statement on the parent segment is executed before an OPENFILE on the child segment.
AionDS runtime errors .........................................................................................................................................................................................................˝.......................................... 20203 Invalid field or variable name The DL/I select field value is unknown. .........................................................................................................................................................................................................˝.......................................... 20204 Invalid variable record length; not within AionDS record length The variable record length specified for the KDL PUTREC statement is invalid because it exceeds the AionDS record length. The AionDS record length is computed according to the record definition in the base type of the file parameter. .........................................................................................................................................................................................................˝.......................................... 20300 File not found (PC/WIN/OS2/PM/SUN/AIX) The requested record I/O processing cannot be performed because the file cannot be found. Check for a valid path and filename. .........................................................................................................................................................................................................˝.......................................... 20300 Member specification not allowed (MVS/VM) A member of a partitioned dataset cannot be used for the requested record I/O processing. .........................................................................................................................................................................................................˝.......................................... 20301 Retrieved record with incorrect record length (PC/WIN/OS2/PM/SUN/AIX) The length of the record retrieved is smaller than the associated AionDS record definition. Check that the record definition correctly matches the external data format. .........................................................................................................................................................................................................˝.......................................... 20301 20301 Dataset record length inconsistent with type definition (MVS) File record length inconsistent with type definition (VM) The record length of the file is smaller than the associated AionDS record definition. Check that the record definition correctly matches the external data format. AionDS Runtime Errors 1-113
- Page 75 and 76: AionDS runtime errors .............
- Page 77 and 78: AionDS runtime errors .............
- Page 79 and 80: AionDS runtime errors To correct th
- Page 81 and 82: AionDS runtime errors .............
- Page 83 and 84: AionDS runtime errors .............
- Page 85 and 86: AionDS runtime errors .............
- Page 87 and 88: AionDS runtime errors .............
- Page 89 and 90: AionDS runtime errors .............
- Page 91 and 92: AionDS runtime errors Execution Con
- Page 93 and 94: AionDS runtime errors .............
- Page 95 and 96: AionDS runtime errors .............
- Page 97 and 98: AionDS runtime errors .............
- Page 99 and 100: AionDS runtime errors At edit time
- Page 101 and 102: AionDS runtime errors .............
- Page 103 and 104: AionDS runtime errors .............
- Page 105 and 106: AionDS runtime errors .............
- Page 107 and 108: AionDS runtime errors .............
- Page 109 and 110: AionDS runtime errors .............
- Page 111 and 112: AionDS runtime errors .............
- Page 113 and 114: AionDS runtime errors Reminder: In
- Page 115 and 116: AionDS runtime errors .............
- Page 117 and 118: AionDS runtime errors .............
- Page 119 and 120: AionDS runtime errors .............
- Page 121 and 122: AionDS runtime errors .............
- Page 123 and 124: AionDS runtime errors .............
- Page 125: AionDS runtime errors .............
- Page 129 and 130: AionDS runtime errors .............
- Page 131 and 132: AionDS runtime errors .............
- Page 133 and 134: AionDS runtime errors .............
- Page 135 and 136: AionDS runtime errors .............
- Page 137 and 138: AionDS runtime errors .............
- Page 139 and 140: AionDS runtime errors .............
- Page 141 and 142: AionDS runtime errors .............
- Page 143 and 144: AionDS runtime errors .............
- Page 145 and 146: AionDS runtime errors AionDS suppor
- Page 147 and 148: AionDS runtime errors .............
- Page 149 and 150: AionDS runtime errors .............
- Page 151 and 152: AionDS runtime errors .............
- Page 153 and 154: AionDS runtime errors .............
- Page 155 and 156: AionDS runtime errors .............
- Page 157 and 158: AionDS runtime errors .............
- Page 159 and 160: AionDS runtime errors .............
- Page 161 and 162: AionDS runtime errors .............
- Page 163 and 164: AionDS runtime errors .............
- Page 165 and 166: AionDS runtime errors .............
- Page 167 and 168: AionDS runtime errors .............
- Page 169 and 170: AionDS runtime errors .............
- Page 171 and 172: AionDS runtime errors .............
- Page 173 and 174: AionDS runtime errors .............
- Page 175 and 176: AionDS runtime errors .............
<strong>AionDS</strong> runtime errors<br />
.........................................................................................................................................................................................................˝..........................................<br />
20203<br />
Invalid field or variable name<br />
The DL/I select field value is unknown.<br />
.........................................................................................................................................................................................................˝..........................................<br />
20204<br />
Invalid variable record length; not within <strong>AionDS</strong> record length<br />
The variable record length specified for the KDL PUTREC statement is<br />
invalid because it exceeds the <strong>AionDS</strong> record length. The <strong>AionDS</strong> record<br />
length is computed according to the record definition in the base type of the<br />
file parameter.<br />
.........................................................................................................................................................................................................˝..........................................<br />
20300<br />
File not found (PC/WIN/OS2/PM/SUN/AIX)<br />
The requested record I/O processing cannot be performed because the file<br />
cannot be found. Check for a valid path <strong>and</strong> filename.<br />
.........................................................................................................................................................................................................˝..........................................<br />
20300<br />
Member specification not allowed (MVS/VM)<br />
A member of a partitioned dataset cannot be used for the requested record<br />
I/O processing.<br />
.........................................................................................................................................................................................................˝..........................................<br />
20301<br />
Retrieved record with incorrect record length<br />
(PC/WIN/OS2/PM/SUN/AIX)<br />
The length of the record retrieved is smaller than the associated <strong>AionDS</strong><br />
record definition. Check that the record definition correctly matches the<br />
external data format.<br />
.........................................................................................................................................................................................................˝..........................................<br />
20301<br />
20301<br />
Dataset record length inconsistent with type definition (MVS)<br />
File record length inconsistent with type definition (VM)<br />
The record length of the file is smaller than the associated <strong>AionDS</strong> record<br />
definition. Check that the record definition correctly matches the external<br />
data format.<br />
<strong>AionDS</strong> Runtime Errors 1-113