Visual Indicator Audible Alarm Condition<br />

Back-Up Backup Alarm Reverse gear is selected<br />

Hazard Click Four-way flashers activated<br />

DRL None Daytime Running Lights<br />

High Beam None Headlamp high beams activated<br />

Kneel Kneel Horn Suspension kneeling system activated<br />

Left Turn Signal Click Left turn signal activated<br />

Parking Brake None Parking brake is activated<br />

Rear Door None Rear passenger door is not closed and locked<br />

Right Turn Signal Click Right turn signal activated<br />

Stop Request Chime Passenger stop request has been activated<br />

Wheelchair Request Double Chime Passenger wheelchair lift request has been<br />

activated<br />

The instrument panel shall include a speedometer indicating no more than 80 mph and calibrated in<br />

maximum increments of 5 mph. The speedometer shall be a rotating pointer type, with a dial<br />

deflection of 220 to 270 degrees and 40 mph near the top of the dial. The speedometer shall be sized<br />

and accurate in accordance with SAE Re<strong>com</strong>mended Practice J678.<br />

Baseline: Use for hubodometer.<br />

The bus shall be equipped with a<br />

hubodometer mounted at the curb side end of<br />

the rear axle. The hubodometer shall have a<br />

capacity reading no less than 999,999 miles.<br />

Alternative: Use for odometer integrated with<br />

the speedometer.<br />

The speedometer shall equipped with an<br />

odometer with a capacity reading no less than<br />

999,999 miles.<br />

The instrument panel shall also include air brake reservoir pressure gauge(s) with indicators for<br />

primary and secondary air tanks and voltmeter(s) to indicate the operating voltage across the bus<br />

batteries. The instrument panel and wiring shall be easily accessible for service from the operator's<br />

seat or top of the panel. Wiring shall have sufficient length and be routed to permit service without<br />

stretching or chafing the wires.<br />

5.4.6.1.6 On-board Diagnostics<br />

The bus shall be equipped with an on-board diagnostic system that will indicate conditions that<br />

require immediate action by the operator to avoid an unsafe condition or prevent further damage to<br />

the bus. This diagnostic system shall have visual and audible indicators. The diagnostic indicator<br />

lamp panel shall be located in clear sight of the operator but need not be immediately in front of him.<br />

The intensity of indicator lamps shall permit easy determination of on/off status in bright sunlight but<br />

shall not cause a distraction or visibility problem at night. All indicators shall have a method of<br />

momentarily testing the operation of the lamp. The audible alarm shall be temper resistant and shall<br />

have an outlet level between 80 and 83 dBA when measured at the location of the operator's ear.<br />

Wherever possible, sensors shall be of the closed circuit type, so that failure of the circuit and/or<br />

Technical Specifications 175 10/18/07