Page 12 of 92<br />

IEC 60950-1 / EN 60950-1<br />

Clause Requirement – Test Result – Remark Verdict<br />

1.5.8 Components in equipment for IT power systems Y1 or Y2 sub-class capacitors<br />

according to IEC 60384-14:1993<br />

provided between phase and<br />

primary ground are rated 250 V.<br />

1.6 Power interface P<br />

1.6.1 AC power distribution systems TN power distribution system<br />

and IT power system only for<br />

Norway.<br />

1.6.2 Input current Highest load according to<br />

1.2.2.1 for this equipment is the<br />

operation of the equipment at<br />

maximum specified DC load at<br />

max. power conditions.<br />

See appended table 1.6.2.<br />

1.6.3 Voltage limit of hand-held equipment The equipment is for buildingin.<br />

1.6.4 Neutral conductor The neutral is not identified in<br />

the equipment. Basic insulation<br />

for rated voltage between<br />

earthed parts and primary<br />

phases.<br />

1.7 Marking and instructions P<br />

1.7.1 Power rating Label is placed on top of metal<br />

chassis. For details see below.<br />

Rated voltage(s) or voltage range(s) (V) .............: 100-240V P<br />

Symbol for nature of supply, for d.c. only .............: AC mains supply N<br />

Rated frequency or rated frequency range (Hz) ..: 47-63 Hz P<br />

Rated current (mA or A) ......................................: 1. 40-20<br />

Manufacturer’s name or trademark or identification<br />

mark .....................................................................:<br />

2. 30-15<br />

3. 20-10<br />

4. 10-5<br />

TRF No.:IECEN60950_1B TRF originator: SGS Fimko<br />

P<br />

P<br />

P<br />

N<br />

P<br />

P<br />

P