Issue Date: 2010-01-29 Page 5 of 69 Report Reference # E143756-A26-UL-2<br />
GENERAL PRODUCT INFORMATION:<br />
CA1.0 Report Summary<br />
CA1.1 N/A<br />
CB1.0 Product Description<br />
CB1.1 The product is an enclosed switch mode power supply intended <strong>for</strong> factory installation as a<br />
component of end product In<strong>for</strong>mation Technology Equipment.<br />
CC1.0 Model Differences<br />
CC1.1 All models are identical except <strong>for</strong> output ratings, model designation and as described in the<br />
<strong>report</strong>.<br />
CD1.0 Additional In<strong>for</strong>mation<br />
CD1.1 Reissue 2:<br />
1. Upgrade Standard 69050-1 2nd Edition;<br />
2. Alternate Varistors source with CCN: VZCA2.<br />
CE1.0 Technical Considerations<br />
CE1.2 The product was submitted and evaluated <strong>for</strong> use at the maximum ambient temperature (Tma)<br />
permitted by the manufacturer’s specification of: 50°C<br />
CE1.3 The means of connection to the mains supply is: Detachable power cord or Pluggable A<br />
CE1.4 The product is intended <strong>for</strong> use on the following power systems: TN<br />
CE1.5 The equipment disconnect device is considered to be: Appliance inlet<br />
CE1.13 The following are available from the Applicant upon request: Specific data sheets <strong>for</strong> LED<br />
indicators that are class I and operate at wavelength in the 400-710 nm range.<br />
CF1.0 Engineering Conditions of Acceptability<br />
CF1.1 For use only in or with complete equipment where the acceptability of the combination is<br />
determined by Underwriters Laboratories Inc.<br />
When installed in an end-product, consideration must be given to the following:<br />
CF1.3 The end-product Electric Strength Test is to be based upon a maximum working voltage of:<br />
Primary-Earthed Dead Metal: 416 Vrms, 800 Vpk, Primary-SELV: 423Vrms, 820 Vpk<br />
CF1.5 The following secondary output circuits are SELV: All outputs<br />
CF1.6 The following secondary output circuits are at hazardous energy levels: Output +5V and +12V<br />
CF1.7 The following secondary output circuits are at non-hazardous energy levels: All outputs except<br />
+5V and +12V.<br />
CF1.10 The following output terminals were referenced to earth during per<strong>for</strong>mance <strong>test</strong>ing: Output (-)<br />