Issue Date: 2010-01-29 Page 56 of 69 Report Reference # E143756-A26-UL-2<br />

IEC 60950-1:2005<br />

Clause Requirement + Test Result - Remark Verdict<br />

Hz original<br />

data from<br />

264V/60<br />

Hz<br />

mA<br />

convert<br />

original<br />

data from<br />

mA<br />

supplementary in<strong>for</strong>mation:<br />

--<br />

2.10.3 and<br />

2.10.4<br />

original<br />

data from<br />

TRF No. IECEN60950_1C Underwriters Laboratories Inc.<br />

mA<br />

-- 440 F1 convert<br />

original<br />

data from<br />

mA<br />

+5V/10.14A, +12V/16A,<br />

+3.3V/16A, -5V/0.5A, -12V/1A,<br />

+5VSB/2A.<br />

Max. normal load. Condition C:<br />

+5V/10.14A, +12V/16A,<br />

+3.3V/16A, -5V/0.5A, -12V/1A,<br />

+5VSB/2A.<br />

TABLE: clearance and cree<strong>page</strong> distance measurements Pass<br />

Clearance (cl) and cree<strong>page</strong><br />

distance (cr) at/of/between:<br />

U peak<br />

(V)<br />

U r.m.s.<br />

(V)<br />

Required cl<br />

(mm)<br />

cl<br />

(mm)<br />

Required cr<br />

(mm)<br />

PRI Component (10N) to earth -- -- -- -- -- --<br />

T2 to earthed screw 420 250 2.0 4.6 2.5 46<br />

PRI Trace to Earth Trace -- -- -- -- -- --<br />

Between CY3 420 250 2.0 6.6 2.5 6.6<br />

Between CY4 420 250 2.0 6.2 2.5 6.2<br />

Between CY5 420 250 2.0 6.6 2.5 6.6<br />

PRI Trace to SEC Trace -- -- -- -- -- --<br />

Between T3 820 423 5.2 12.6 8.6 12.6<br />

Between T4 592 341 4.6 12.8 7.2 12.8<br />

Between U6 420 250 4.0 6.4 5.0 6.4<br />

Between U7 420 250 4.0 7.0 5.0 7.0<br />

Between U8 420 250 4.0 7.0 5.0 7.0<br />

R1 to Q11 420 250 4.0 5.1 5.0 5.1<br />

supplementary in<strong>for</strong>mation:<br />

1. Functional insulation shorted, see sub-clause 5.3.4.<br />

cr<br />

(mm)<br />

2.10.5 TABLE: distance through insulation measurements Pass<br />

Distance through insulation (DTI) at/of: U peak<br />

(V)<br />

Urms<br />

(V)<br />

Test voltage<br />

(V)<br />

Required DTI<br />

(mm)<br />

Photo Couplers (rein<strong>for</strong>ced insulation) 420 250 3000 0.4 >0.4<br />

supplementary in<strong>for</strong>mation:<br />

--<br />

DTI<br />

(mm)