Issue Date: 2010-01-29 Page 56 of 69 Report Reference # E143756-A26-UL-2<br />
IEC 60950-1:2005<br />
Clause Requirement + Test Result - Remark Verdict<br />
Hz original<br />
data from<br />
264V/60<br />
Hz<br />
mA<br />
convert<br />
original<br />
data from<br />
mA<br />
supplementary in<strong>for</strong>mation:<br />
--<br />
2.10.3 and<br />
2.10.4<br />
original<br />
data from<br />
TRF No. IECEN60950_1C Underwriters Laboratories Inc.<br />
mA<br />
-- 440 F1 convert<br />
original<br />
data from<br />
mA<br />
+5V/10.14A, +12V/16A,<br />
+3.3V/16A, -5V/0.5A, -12V/1A,<br />
+5VSB/2A.<br />
Max. normal load. Condition C:<br />
+5V/10.14A, +12V/16A,<br />
+3.3V/16A, -5V/0.5A, -12V/1A,<br />
+5VSB/2A.<br />
TABLE: clearance and cree<strong>page</strong> distance measurements Pass<br />
Clearance (cl) and cree<strong>page</strong><br />
distance (cr) at/of/between:<br />
U peak<br />
(V)<br />
U r.m.s.<br />
(V)<br />
Required cl<br />
(mm)<br />
cl<br />
(mm)<br />
Required cr<br />
(mm)<br />
PRI Component (10N) to earth -- -- -- -- -- --<br />
T2 to earthed screw 420 250 2.0 4.6 2.5 46<br />
PRI Trace to Earth Trace -- -- -- -- -- --<br />
Between CY3 420 250 2.0 6.6 2.5 6.6<br />
Between CY4 420 250 2.0 6.2 2.5 6.2<br />
Between CY5 420 250 2.0 6.6 2.5 6.6<br />
PRI Trace to SEC Trace -- -- -- -- -- --<br />
Between T3 820 423 5.2 12.6 8.6 12.6<br />
Between T4 592 341 4.6 12.8 7.2 12.8<br />
Between U6 420 250 4.0 6.4 5.0 6.4<br />
Between U7 420 250 4.0 7.0 5.0 7.0<br />
Between U8 420 250 4.0 7.0 5.0 7.0<br />
R1 to Q11 420 250 4.0 5.1 5.0 5.1<br />
supplementary in<strong>for</strong>mation:<br />
1. Functional insulation shorted, see sub-clause 5.3.4.<br />
cr<br />
(mm)<br />
2.10.5 TABLE: distance through insulation measurements Pass<br />
Distance through insulation (DTI) at/of: U peak<br />
(V)<br />
Urms<br />
(V)<br />
Test voltage<br />
(V)<br />
Required DTI<br />
(mm)<br />
Photo Couplers (rein<strong>for</strong>ced insulation) 420 250 3000 0.4 >0.4<br />
supplementary in<strong>for</strong>mation:<br />
--<br />
DTI<br />
(mm)