Issue Date: 2010-01-29 Page 23 of 69 Report Reference # E143756-A26-UL-2<br />

IEC 60950-1:2005<br />

Clause Requirement + Test Result - Remark Verdict<br />

3.2 Connection to mains supply Pass<br />

3.2.1 Means of connection Pass<br />

3.2.1.1 Connection to an a.c. mains supply The unit is provided with an<br />

appliance inlet.<br />

3.2.1.2 Connection to a d.c. mains supply N/A<br />

3.2.2 Multiple supply connections N/A<br />

3.2.3 Permanently connected equipment N/A<br />

Number of conductors, diameter of cable and<br />

conduits (mm) ................................................... :<br />

3.2.4 Appliance inlets The appliance inlet complies<br />

with IEC 60320.<br />

3.2.5 Power supply cords Cord not provided. N/A<br />

3.2.5.1 AC power supply cords N/A<br />

Type................................................................. : -<br />

Rated current (A), cross-sectional area (mm²),<br />

AWG ................................................................ :<br />

3.2.5.2 DC power supply cords N/A<br />

3.2.6 Cord anchorages and strain relief N/A<br />

Mass of equipment (kg), pull (N)......................... : -<br />

Longitudinal displacement (mm) ......................... : -<br />

3.2.7 Protection against mechanical damage N/A<br />

3.2.8 Cord guards N/A<br />

Diameter of minor dimension D (mm); <strong>test</strong> mass (g)<br />

........................................................................ :<br />

Radius of curvature of cord (mm)........................ : -<br />

3.2.9 Supply wiring space N/A<br />

TRF No. IECEN60950_1C Underwriters Laboratories Inc.<br />

Pass<br />

-<br />