Issue Date: 2010-01-29 Page 16 of 69 Report Reference # E143756-A26-UL-2<br />
IEC 60950-1:2005<br />
Clause Requirement + Test Result - Remark Verdict<br />
2.6.5.2 Components in protective earthing conductors and<br />
protective bonding conductors<br />
TRF No. IECEN60950_1C Underwriters Laboratories Inc.<br />
No switch or overcurrent<br />
protective device in protective<br />
earthing or bonding conductor.<br />
2.6.5.3 Disconnection of protective earth Disconnection of the protective<br />
earth at one assembly<br />
removes connection of<br />
HAZARDOUS VOLTAGES<br />
from the other assemblies at<br />
the same time.<br />
2.6.5.4 Parts that can be removed by an operator Protective earth required<br />
makes earlier and breaks later<br />
than the supply connectors.<br />
2.6.5.5 Parts removed during servicing Connections to protective<br />
earthing can be removed<br />
unless hazardous voltage is<br />
removed from the part<br />
simultaneously.<br />
2.6.5.6 Corrosion resistance No risk of corrosion. Complies<br />
with Annex J.<br />
2.6.5.7 Screws <strong>for</strong> protective bonding Metal thickness at least twice<br />
the pitch of the screw.<br />
At least two screws used.<br />
2.6.5.8 Reliance on telecommunication network or cable<br />
distribution system<br />
Pass<br />
Pass<br />
Pass<br />
Pass<br />
Pass<br />
Pass<br />
No TNV. N/A