19.06.2013 Views

drivers of soil respiration of root and microbial ... - Unitus DSpace

drivers of soil respiration of root and microbial ... - Unitus DSpace

drivers of soil respiration of root and microbial ... - Unitus DSpace

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

• Another half <strong>of</strong> the sampled <strong>and</strong> sieved <strong>soil</strong> was placed back without any barriers for the<br />

<strong>root</strong>s growing (bags with 1.0 cm pore size). The CO2 efflux, coming from these bags is a<br />

sum <strong>of</strong> <strong>microbial</strong> <strong>and</strong> <strong>root</strong>-derived <strong>respiration</strong> (Rh+Ra).<br />

• Root-derived <strong>respiration</strong> was calculated as a difference between these two treatments:<br />

((Rh+Ra)-Rh).<br />

• Total <strong>soil</strong> <strong>respiration</strong> (Rs) measured from the undisturbed <strong>soil</strong> was used as a control <strong>and</strong> in<br />

Summarizing:<br />

combination with <strong>root</strong>-derived <strong>respiration</strong> was used to calculate the real <strong>microbial</strong>-derived<br />

<strong>respiration</strong>: (Rs – Ra).<br />

1µm = <strong>microbial</strong>-derived <strong>respiration</strong> (Rh), after disturbing<br />

1 cm = sum <strong>of</strong> <strong>microbial</strong> <strong>and</strong> <strong>root</strong>-derived <strong>respiration</strong> (Rh+Ra)<br />

1cm - 1µm = <strong>root</strong>-derived <strong>respiration</strong> (Ra)<br />

No mesh = control for total <strong>respiration</strong> (Rs)<br />

Control - Ra = <strong>microbial</strong> derived <strong>respiration</strong> (Rh), excluding the effect <strong>of</strong> <strong>soil</strong> sieving<br />

2.2.3. Eddy covariance data<br />

Ecosystem net carbon <strong>and</strong> water vapour fluxes have been measured at Amplero<br />

continuously since 2002. The eddy covariance system integrates a sonic anemometer (Solent R3,<br />

Gill Instruments, Lymington, UK) <strong>and</strong> a LI 7500 open path infrared gas analyzer (LiCor, Lincoln,<br />

NE, USA). The flux data were calculated for 30 min intervals by means <strong>of</strong> the post-processing<br />

program Eddyflux.<br />

GPP was calculated from the difference between NEE <strong>and</strong> TER (Reichstein et al., 2005),<br />

where functional dependencies <strong>of</strong> total ecosystem <strong>respiration</strong> (TER) with temperatures were<br />

determined with CO2 fluxes measured at night (fluxes measured during low mixed periods were<br />

discarded, Aubinet et al., 2000). These functions were then applied to daytime data to derive GPP.<br />

GPP was estimated for the year 2006 <strong>and</strong> 2007, data <strong>of</strong> 2008 are still under elaboration.<br />

39

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!