drivers of soil respiration of root and microbial ... - Unitus DSpace
drivers of soil respiration of root and microbial ... - Unitus DSpace
drivers of soil respiration of root and microbial ... - Unitus DSpace
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
• Another half <strong>of</strong> the sampled <strong>and</strong> sieved <strong>soil</strong> was placed back without any barriers for the<br />
<strong>root</strong>s growing (bags with 1.0 cm pore size). The CO2 efflux, coming from these bags is a<br />
sum <strong>of</strong> <strong>microbial</strong> <strong>and</strong> <strong>root</strong>-derived <strong>respiration</strong> (Rh+Ra).<br />
• Root-derived <strong>respiration</strong> was calculated as a difference between these two treatments:<br />
((Rh+Ra)-Rh).<br />
• Total <strong>soil</strong> <strong>respiration</strong> (Rs) measured from the undisturbed <strong>soil</strong> was used as a control <strong>and</strong> in<br />
Summarizing:<br />
combination with <strong>root</strong>-derived <strong>respiration</strong> was used to calculate the real <strong>microbial</strong>-derived<br />
<strong>respiration</strong>: (Rs – Ra).<br />
1µm = <strong>microbial</strong>-derived <strong>respiration</strong> (Rh), after disturbing<br />
1 cm = sum <strong>of</strong> <strong>microbial</strong> <strong>and</strong> <strong>root</strong>-derived <strong>respiration</strong> (Rh+Ra)<br />
1cm - 1µm = <strong>root</strong>-derived <strong>respiration</strong> (Ra)<br />
No mesh = control for total <strong>respiration</strong> (Rs)<br />
Control - Ra = <strong>microbial</strong> derived <strong>respiration</strong> (Rh), excluding the effect <strong>of</strong> <strong>soil</strong> sieving<br />
2.2.3. Eddy covariance data<br />
Ecosystem net carbon <strong>and</strong> water vapour fluxes have been measured at Amplero<br />
continuously since 2002. The eddy covariance system integrates a sonic anemometer (Solent R3,<br />
Gill Instruments, Lymington, UK) <strong>and</strong> a LI 7500 open path infrared gas analyzer (LiCor, Lincoln,<br />
NE, USA). The flux data were calculated for 30 min intervals by means <strong>of</strong> the post-processing<br />
program Eddyflux.<br />
GPP was calculated from the difference between NEE <strong>and</strong> TER (Reichstein et al., 2005),<br />
where functional dependencies <strong>of</strong> total ecosystem <strong>respiration</strong> (TER) with temperatures were<br />
determined with CO2 fluxes measured at night (fluxes measured during low mixed periods were<br />
discarded, Aubinet et al., 2000). These functions were then applied to daytime data to derive GPP.<br />
GPP was estimated for the year 2006 <strong>and</strong> 2007, data <strong>of</strong> 2008 are still under elaboration.<br />
39