TORCIA IN-GROUND LIGHT<br />

<strong>In</strong>stallation instructions for TG1-12V-WW-SS<br />

READ ALL OF THESE INSTALLATION INSTRUCTIONS BEFORE INSTALLING THE FIXTURE. FAILURE TO<br />

FOLLOW INSTALLATION INSTRUCTIONS AND ALL APPLICABLE ELECTRICAL CODES WILL VOID THE<br />

PRODUCT WARRANTY.<br />

WARNING:<br />

These products may represent a possible shock or fire hazard if improperly installed or attached in any<br />

way. Products should be installed in accordance with these instructions, current electrical codes and/or<br />

the current National Electric Code (NEC).<br />

WARNING:<br />

Disconnect supply power from the source prior to installation. This product must be installed by a<br />

person familiar with the construction and operation of the product and the hazards involved, and in<br />

accordance with current electrical codes and/or the current National Electric Code (NEC) for two wire<br />

installation. Consult a local licensed electrician if you are not sure about the installation.<br />

APPLICATION / USE:<br />

This product is designed for recessed mounting only. Appropriate installations include mounting into a<br />

concrete slab or retaining wall using the black PVC sleeve included with the fixture; into the earth using the<br />

black PVC sleeve included; or into an interior or exterior wall with or without the black PVC sleeve. For any<br />

outdoor or other wet location installation where the PVC sleeve is used vertically, the PVC sleeve must have proper<br />

drainage to avoid immersion in water! The <strong>Torcia</strong> <strong>In</strong>-<strong>Ground</strong> <strong>Light</strong> may come into contact with water, but may<br />

not be immersed in water.<br />

LAYOUT AND SELECTION OF RECOMMENDED CONSTANT VOLTAGE DRIVER<br />

The <strong>Torcia</strong> <strong>In</strong>-<strong>Ground</strong> <strong>Light</strong> (1.4W each) requires a regulated 12V driver with a DC output.<br />

<strong>American</strong> <strong>Light</strong>ing recommends the following drivers as a function of how many fixtures are attached:<br />

Quantity LED-DR-12 LED-DR60-12 LED-DR100-12<br />

(1-25 watts) (1-60 watts) (1-100 watts)<br />

1-17 <br />

18-42 <br />

43-71 <br />

NOTE: FOR OUTDOOR INSTALLATIONS THE CONSTANT VOLTAGE DRIVER MUST BE ENCLOSED IN A WATER-<br />

PROOF ENCLOSURE. All conductors and power connections must be installed per current state and local<br />

electrical codes. Drivers must be mounted properly inside enclosure and also must have clearance above<br />

and around for proper heat dissipation.<br />

IN-GROUND / SOIL INSTALLATION:<br />

Note: Debris must be kept away from the lens to allow proper operation and optimize light output. <strong>In</strong>spect<br />

the installed fixture periodically to ensure that the lens is kept clean and free of dirt, dust, plants, leaves and<br />

any other kind of obstruction. Adhering to a regular maintenance schedule is advised.<br />

<strong>Torcia</strong> <strong>Light</strong>s have certain other installation requirements and considerations:<br />

1. Provide proper drainage for PVC sleeve so that fixtures will not be immersed in water (see also next page).<br />

2. Do not locate fixtures in low areas where water will collect.<br />

3. Make sure trim is flush to 1/8” above finish grade to prevent water from accumulating on lens.<br />

4. <strong>In</strong> turf applications, it is recommended to keep grass away from fixture using borders or concrete or some<br />

kind of landscape material so that lawn equipment will not damage the fixture or its installation.<br />

www.americanlighting.com<br />

©2012 <strong>American</strong> <strong>Light</strong>ing<br />

Denver, CO 80231 Made in China


TORCIA IN-GROUND LIGHT<br />

<strong>In</strong>stallation instructions for TG1-12V-WW-SS (continued)<br />

IN-GROUND / SOIL INSTALLATION: (continued from page 1)<br />

Be sure power to the junction box has been shut off at the main.<br />

1. Determine location of fixtures in relation to each other and to the power supply. Note: Larger distances<br />

from the power supply will create loss of initial voltage (voltage drop). If voltage drop becomes too large,<br />

the light output will be noticeably less. <strong>In</strong> order to keep voltage drop from affecting light output, keep<br />

fixtures within 35 feet of the power supply and use 16-gauge wire or larger (see also part 4 below).<br />

2. For each fixture location, dig approximately 9” diameter hole, 10” deep.<br />

3. Add 4-6” drainage material (such as pea gravel and/or sand) in each hole.<br />

4. Push fixture barrel into PVC sleeve. Rubber gasket must be a tight fit. It will require pressure to seat fully.<br />

5. Using 2-conductor wire rated for direct burial applications, wire each fixture to the power supply in a<br />

parallel wiring configuration (homerun back to the power supply).<br />

6. Make secure wire connections using UL Listed direct burial wire nuts (not included), matching polarity:<br />

brown wire is positive (+), blue wire is negative (-). Note: <strong>In</strong> order for the <strong>Torcia</strong> fixture to light, the wiring<br />

must have proper polarity in relation to the power supply’s output. If reversed, this will not damage the<br />

fixture or the LED, it simply will not illuminate until polarity is correct and connections are solid.<br />

7. Test light by connecting lead wire to power supply and restoring power at the main.<br />

8. Coil any extra lead wire below the fixture/PVC sleeve.<br />

8. Backfill hole with pea gravel or sand.<br />

9. Repeat with additional fixtures.<br />

CONCRETE POUR INSTALLATION:<br />

Be sure power to the junction box has been shut off at the main.<br />

1. Repeat steps 1-3 above except hole should be 6” deep.<br />

2. Run rigid conduit to each location and pull 2-conductor wire, 16-gauge or larger leaving 18” extra<br />

wire length at each fixture location.<br />

3. Using standard masonry techniques , anchor and plug each PVC sleeve in upright position at slab<br />

finish height. Be sure to pull extra length wire up through each PVC sleeve.<br />

4. Add drainage material around the PVC sleeve to grade height.<br />

5. After slab has been poured and is set, follow steps 4-7 above, but test each fixture BEFORE seating it<br />

into PVC sleeve.<br />

6. Coil extra lead into sleeve (cut back extra if wire will not fit).<br />

7. Repeat with additional fixtures.<br />

ADDITIONAL SAFETY MEASURES:<br />

1. LEDs are not serviceable. Do not attempt to open the LED light engine.<br />

2. LEDs are bright. Do not look directly into fixture.<br />

3. Not intended for surface mounting in any type of installation.<br />

4. Do not alter fixture.<br />

www.americanlighting.com<br />

©2012 <strong>American</strong> <strong>Light</strong>ing<br />

Denver, CO 80231 Made in China