17.06.2013 Views

LPF 1000 AR 144

LPF 1000 AR 144

LPF 1000 AR 144

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>LPF</strong> <strong>1000</strong> <strong>AR</strong> <strong>144</strong><br />

Italian Technology Broadcast<br />

____________________________________________________________ January 2011 – First Ediction___<br />

LOW PASS FILTER <strong>144</strong> MHz – 1 KW<br />

_________________________________________________________________________________________<br />

GENERAL CH<strong>AR</strong>ACTERISTICS<br />

OPTIONS<br />

Frequency Range 140 ÷ 150 MHz<br />

Input Power MAX <strong>1000</strong> W<br />

S.W.R. input (@ <strong>144</strong> MHz ) ≥ - 30dB<br />

Insertion Loss ≤ 0,18 dB<br />

second harmonic attenuation (@ <strong>144</strong> MHz ) ≥ - 60 dBc<br />

Input – Output Impedance 50 Ω<br />

PC Board Teflon<br />

Working Temperature 0 ÷ 80°C MAX<br />

Weight 100 g. ± 2%<br />

Dimension 100 X 75 mm<br />

Measure Direct Power OPTION<br />

Measure Reflected Power OPTION<br />

* The above data is purely indicative, Italab may vary them without any warning<br />

Italab Communications<br />

via Casale 3/a, cap. 20<strong>144</strong> Milano ( Italy )<br />

Phone: 0039 02 90389417 – Fax : 0039 02 23168389<br />

mail: info@italab.it web site : www.italab.it


<strong>LPF</strong> <strong>1000</strong> <strong>AR</strong> <strong>144</strong><br />

Italian Technology Broadcast<br />

____________________________________________________________ January 2011 – First Ediction___<br />

IN RF<br />

PWR OUT<br />

OUT RF<br />

SWR OUT<br />

Outputs "PWR OUT" and "SWR OUT", give a DC voltage which should best be elaborated at length<br />

to optimize the reading of an analog instrument to 100µA.<br />

We recommend that you use only and only 50 Ω cable Teflon for connections "IN - OUT because the<br />

energy involved is substantial (@ 1 kW).<br />

Use of adequate support for fixing screws in the holes prepared, but 2.5.<br />

Le Uscite “ PWR OUT “ e “SWR OUT”, danno una tensione continua che và opportunamente<br />

elaborata alfine di ottimizzare la lettura su uno strumento analogico da 100µA.<br />

Si consiglia di usare solo e unicamente cavo 50 Ω in teflon per le connessioni “ IN – OUT in quanto<br />

l’energia in gioco è notevole ( @ 1 KW ).<br />

Usare per il fissaggio su adeguato supporto viti 2.5 ma nelle forature predisposte.


5<br />

5<br />

4<br />

4<br />

3<br />

D D<br />

FREQ-IN<br />

C1<br />

CAP<br />

L1<br />

ITALIND1<br />

C2<br />

CAP<br />

L2<br />

ITALIND1<br />

C3<br />

CAP<br />

L3<br />

ITALIND1<br />

C4<br />

CAP<br />

L4<br />

ITALIND1<br />

C5<br />

CAP<br />

R3<br />

C6<br />

CAP<br />

C C<br />

B B<br />

A A<br />

3<br />

C7<br />

CAP<br />

D1<br />

R1<br />

C8<br />

CAP<br />

C9<br />

CAP<br />

C10<br />

CAP<br />

R2<br />

D2<br />

R4<br />

2<br />

Title<br />

Size Document Number Design<br />

Rev<br />

A4<br />

MD3000BX-FM Micalizzi 05-2010<br />

2<br />

C11<br />

CAP<br />

PWR_COUPLER<br />

FREQ_OUT<br />

SWR_COUPLER<br />

ITB<br />

Italian Technology of Broadcast MILANO ( ITALY )<br />

Schematic Filter and Coupler 1KW <strong>144</strong> MHz<br />

Date: Tuesday, December 06, 2011 Sheet 1 of 1<br />