3. SEISMIC BEHAVIOUR OF BOLTED END PLATE BEAM-TO-COLUMN STEEL JOINTS<br />

Full strength joint: m ≥ 1<br />

( 3.13 )<br />

Partial strength joint: 0,25 ≤ m ≤ 1<br />

( 3.14 )<br />

Nominally pinned joint: m ≤ 0,25<br />

( 3.15 )<br />

Fur<strong>the</strong>rmore, all <strong>the</strong> considered joints can be classified as partial strength joints, as<br />

illustrated in Figure 3.21 for <strong>the</strong> JA1-2 specimen endowed with an end plate<br />

thickness <strong>of</strong> 12 mm <strong>and</strong> in Figure 3.22 for <strong>the</strong> JB1-3 specimens endowed with an<br />

end plate thickness <strong>of</strong> 18 mm.<br />

68<br />

M/M pl,Rd<br />

1.2<br />

1<br />

0.8<br />

0.6<br />

0.4<br />

0.2<br />

0<br />

Limit = 35 mrad<br />

JA1-2A<br />

JA1-2B<br />

JA1-2M<br />

0 0.2 0.4 0.6 0.8 1 1.2<br />

φ/(M pl,Rd L b /E s I b )<br />

Figure 3.21. Classification <strong>of</strong> <strong>the</strong> JA1-2 Complete<br />

Joint for Lb = 8m