3. SEISMIC BEHAVIOUR OF BOLTED END PLATE BEAM-TO-COLUMN STEEL JOINTS<br />

amplitude testing. The different loading histories considered are built up to<br />

appraise <strong>the</strong> influence on <strong>the</strong> cyclic joint response, <strong>and</strong> in particular on <strong>the</strong> damage<br />

evolution, <strong>of</strong> different sequences <strong>of</strong> cycle amplitudes, simulating some features <strong>of</strong><br />

<strong>the</strong> <strong>seismic</strong> input. Tests were carried out quasi-statically. Therefore, an increase in<br />

<strong>the</strong> ductility capacity compared to equivalent specimens loaded dynamically would<br />

be expected, considering that fracture toughness <strong>of</strong> steel decreases with <strong>the</strong> strain<br />

rate growth. However, tests on welded beam-to-column connections performed by<br />

Suita et al. (1998) pointed out <strong>the</strong> equivalence between quasi-static <strong>and</strong> dynamic<br />

tests with regard to ductility. Moreover, <strong>the</strong> strength as well as <strong>the</strong> absorbed energy<br />

is larger for dynamic loading than for quasi-static loading confirming that quasi-<br />

static test procedures lead to a conservative appraisal <strong>of</strong> <strong>the</strong>se key parameters.<br />

3.5 Main results <strong>and</strong> preliminary <strong>seismic</strong> assessment<br />

The results <strong>of</strong> <strong>the</strong> study are briefly presented in this section, focused on <strong>the</strong><br />

experimental outcomes <strong>and</strong> <strong>the</strong>ir first assessment in <strong>the</strong> perspective <strong>of</strong> <strong>seismic</strong><br />

design. The three sets <strong>of</strong> tests are here considered separately. The significance <strong>of</strong><br />

<strong>the</strong>se results in view <strong>of</strong> <strong>the</strong> validation <strong>of</strong> <strong>the</strong> component method is dealt with in<br />

Section 3.6.<br />

3.5.1 Isolated Tee stubs<br />

The applied load versus <strong>the</strong> upward displacement curves <strong>of</strong> <strong>the</strong> Tee stub web<br />

represent an important overall indicator <strong>of</strong> <strong>the</strong> specimen’s <strong>behaviour</strong> to be<br />

associated with <strong>the</strong> failure mode in order to underst<strong>and</strong> <strong>the</strong> influence <strong>of</strong> <strong>the</strong><br />

parameters investigated, i.e., <strong>the</strong> plate thickness, <strong>the</strong> bolt diameter <strong>and</strong> <strong>the</strong>ir ratio.<br />

Figure 3.10 illustrates a typical Tee stub response with reference to <strong>the</strong> case <strong>of</strong> 12<br />

mm end plate thickness t <strong>and</strong> 20 mm diameter bolts. Both <strong>the</strong> monotonic <strong>and</strong> cyclic<br />

responses are plotted, showing that <strong>the</strong> envelope <strong>of</strong> <strong>the</strong> latter one lies very close to<br />

<strong>the</strong> monotonic curve for a first significant portion <strong>of</strong> <strong>the</strong> loading process.<br />

Progressive strength deterioration, associated to <strong>the</strong> increase <strong>of</strong> end plate plastic<br />

deformations <strong>and</strong> damage at <strong>the</strong> weld toe, is <strong>the</strong>n occurring. As illustrated in Figure<br />

3.11, at <strong>the</strong> ultimate limit state <strong>the</strong> TM-2 specimen was characterized by a collapse<br />

mechanism with four yield lines located at <strong>the</strong> bolt-holes <strong>and</strong> at <strong>the</strong> weld toes in<br />

accordance with Mode 1 failure (Eurocode 3, 2001). The corresponding specimen<br />

58