3. SEISMIC BEHAVIOUR OF BOLTED END PLATE BEAM-TO-COLUMN STEEL JOINTS<br />

48<br />

Specimen t p Bolt diameter Column t cf Displacement<br />

(mm) (mm) (mm) test procedure<br />

JA1-2A 12 20 HEA180 9.5 SDTP - 1<br />

JA1-2B 12 20 HEA180 9.5 SDTP - 1<br />

JA1-2C 12 20 HEA180 9.5 SDTP - 3<br />

JA1-2D 12 20 HEA180 9.5 SDTP - 4<br />

JA1-2E 12 20 HEA180 9.5 SDTP - 5<br />

JA1-2E 12 20 HEA180 9.5 SDTP - 6<br />

JA1-2M 12 20 HEA180 9.5 Monotonic<br />

JA1-2R 12 20 HEA180 9.5 SDTP - 7<br />

JB1-3A 18 20 HEB180 14 SDTP - 1<br />

JB1-3B 18 20 HEB180 14 SDTP - 1<br />

JB1-3C 18 20 HEB180 14 SDTP - 3<br />

JB1-3D 18 20 HEB180 14 SDTP - 4<br />

JB1-3E 18 20 HEB180 14 SDTP - 5<br />

JB1-3F 18 20 HEB180 14 SDTP - 6<br />

JB1-3M 18 20 HEB180 14 Monotonic<br />

JB1-3R 18 20 HEB180 14 SDTP - 7<br />

JB1-4 18 24 HEB180 14 SDTP - 1<br />

JA2-4 18 24 HEA280 13 SDTP - 1<br />

Table 3.3. Properties <strong>of</strong> Complete Joints<br />

All bolts are 8.8 grade bolts preloaded to <strong>the</strong> 40% <strong>of</strong> <strong>the</strong> actual yield strength in<br />

order to roughly simulate <strong>the</strong> condition corresponding to <strong>the</strong> pretension induced by<br />

h<strong>and</strong> tightening up to <strong>the</strong> snug tight condition. The geometries <strong>of</strong> <strong>the</strong> components<br />

(Tee stubs, bolts <strong>and</strong> column section) are coupled in such a way to cover a range<br />

<strong>of</strong> relative component stiffness (Tee stub thickness to bolt diameter for <strong>the</strong> isolated<br />

Tee stubs <strong>and</strong> Tee stub thickness to column flange thickness for <strong>the</strong> coupled Tee<br />

stubs <strong>and</strong> full joint specimens) <strong>of</strong> significance for practical interest.