3.1 Introduction<br />
40<br />
3 SEISMIC BEHAVIOUR OF BOLTED END PLATE<br />
BEAM-TO-COLUMN STEEL JOINTS<br />
In <strong>high</strong> <strong>seismic</strong> risk areas such as California <strong>and</strong> Japan, steel-framed buildings<br />
have frequently been employed because <strong>of</strong> <strong>the</strong>ir excellent performances in terms<br />
<strong>of</strong> strength <strong>and</strong> ductility. Never<strong>the</strong>less, a large number <strong>of</strong> entirely unexpected<br />
severe brittle cracks <strong>of</strong> welded beam-to-column connections were found in <strong>the</strong><br />
recent Northridge (1994) <strong>and</strong> Kobe (1995) earthquakes (Bertero et al., 1994,<br />
Kuwamura, 1998). The failures raised many questions regarding <strong>the</strong> validity <strong>of</strong><br />
design <strong>and</strong> construction procedures used for <strong>the</strong>se connections at <strong>the</strong> time. Since<br />
<strong>the</strong> earthquake, several extensive analytical <strong>and</strong> experimental studies have been<br />
conducted to investigate <strong>the</strong> various aspects believed to be associated with <strong>the</strong><br />
failure observed in <strong>the</strong> pre-Northridge connection <strong>and</strong> to improve connection<br />
performance. The majority <strong>of</strong> <strong>the</strong> thorough investigations established that<br />
premature cracking in welded steel connections resulted from a combination <strong>of</strong><br />
factors, such as <strong>high</strong> strain dem<strong>and</strong>s coupled with large inherent flaws <strong>and</strong> stress<br />
risers, overreliance on low-toughness materials, deficient field welding <strong>and</strong><br />
insufficient quality control.<br />
As a result <strong>of</strong> poor performance <strong>of</strong> flange-welded moment connections, end plate<br />
moment connections may represent, especially in Europe, an alternative to welding<br />
in <strong>seismic</strong> regions. But because <strong>of</strong> limited cyclic testing <strong>of</strong> moment end plate<br />
connections, extensive research has been initiated. In <strong>the</strong> framework <strong>of</strong> a research<br />
programme conducted by <strong>the</strong> Department <strong>of</strong> Mechanical <strong>and</strong> Structural<br />
Engineering <strong>of</strong> <strong>the</strong> University <strong>of</strong> Trento <strong>and</strong> sponsored by a MIUR-PRIN project<br />
devoted to <strong>the</strong> analysis <strong>of</strong> semi-rigid beam-to-column connections, <strong>the</strong> presented<br />
study has a two-fold purpose: