10.06.2013 Views

Analysis and modelling of the seismic behaviour of high ... - Ingegneria

Analysis and modelling of the seismic behaviour of high ... - Ingegneria

Analysis and modelling of the seismic behaviour of high ... - Ingegneria

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

5. SEISMIC BEHAVIOUR OF RC COLUMNS EMBEDDING STEEL PROFILES<br />

5.5.3 Global test instrumentation<br />

Different types <strong>of</strong> instruments were used to determine <strong>the</strong> <strong>behaviour</strong> <strong>of</strong> <strong>the</strong><br />

specimens during <strong>the</strong> test, among <strong>the</strong>m strain gauges, load cells, displacement<br />

transducers, inclinometers, etc. Preliminary analyses <strong>of</strong> <strong>the</strong> specimen <strong>and</strong> loading<br />

apparatus, by means <strong>of</strong> FE method, were conducted to estimate <strong>the</strong><br />

displacement/strain/force ranges to be used in selecting <strong>and</strong> calibrating<br />

instruments. Hereafter <strong>the</strong> instrumentation that has been used in monitoring <strong>the</strong><br />

specimens is presented, according to <strong>the</strong> test set-up illustrated in Figure 5.21.<br />

Load cells<br />

• Interior load cell located in <strong>the</strong> vertical actuator (Maximum capacity: 1000 kN in<br />

compression, 650 kN in tension);<br />

• Interior load cell located in <strong>the</strong> horizontal actuator (Maximum capacity: 1000KN<br />

in compression, 1000 KN in tension);<br />

• LC-1: exterior load cell located as hinge (Maximum capacity: 1000 kN);<br />

• LC-2: exterior load cell located as hinge (Maximum capacity: 1000 kN).<br />

Displacement transducers<br />

• Interior LVDT located in <strong>the</strong> vertical actuator (Maximum capacity: 500 mm);<br />

• Interior LVDT located in <strong>the</strong> horizontal actuator (Maximum capacity: 500 mm);<br />

• DT500-Column: exterior digital transducer Heidenhein-USL500 (Maximum<br />

capacity: 500 mm), located at <strong>the</strong> top <strong>of</strong> <strong>the</strong> column;<br />

• DT500-Beam: exterior digital transducer Heidenhein-USL500 (Maximum<br />

capacity: 500 mm), located at <strong>the</strong> mid-height <strong>of</strong> <strong>the</strong> beam.<br />

Digital<br />

Transducer 2<br />

Load Cell n° 1<br />

Digital Transducer 1<br />

Figure 5.22. Exterior digital transducer <strong>and</strong> exterior load cells in <strong>the</strong> specimen<br />

Load Cell n° 2<br />

213

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!