Analysis and modelling of the seismic behaviour of high ... - Ingegneria
Analysis and modelling of the seismic behaviour of high ... - Ingegneria
Analysis and modelling of the seismic behaviour of high ... - Ingegneria
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
4. SEISMIC RESPONSE OF PARTIAL-STRENGTH COMPOSITE JOINTS<br />
The shape <strong>of</strong> <strong>the</strong> cracks on <strong>the</strong> slab was quite <strong>the</strong> same as in test n° 2, even if <strong>the</strong>ir<br />
extension increased <strong>and</strong> spalling <strong>of</strong> <strong>the</strong> compressed concrete at level 1 was<br />
observed, as depicted in Figure 4.57. This last phenomenon was present only on<br />
<strong>the</strong> interior side <strong>of</strong> <strong>the</strong> joints. Gaps between <strong>the</strong> steel column flanges <strong>and</strong> <strong>the</strong><br />
concrete slab were also observed at all joints, both <strong>the</strong> interior <strong>and</strong> <strong>the</strong> exterior<br />
ones.<br />
So as for <strong>the</strong> previous test, at <strong>the</strong> column base no damage developed, no cracking<br />
<strong>and</strong> no local instabilities could be observed. Never<strong>the</strong>less, rotation at <strong>the</strong> base<br />
joints under <strong>the</strong> bending moment transferred by <strong>the</strong> columns was observed during<br />
<strong>the</strong> test. This was mainly due to <strong>the</strong> extension <strong>of</strong> <strong>the</strong> column anchor rods, <strong>and</strong> <strong>the</strong><br />
failure <strong>of</strong> <strong>the</strong> grout in compression. Because <strong>of</strong> <strong>the</strong> gap between <strong>the</strong> upper side <strong>of</strong><br />
<strong>the</strong> base plate <strong>and</strong> <strong>the</strong> nuts, it could be probably stated that yielding <strong>of</strong> <strong>the</strong> anchor<br />
rods had occurred. After <strong>the</strong> test, cracking were also noticed in <strong>the</strong> concrete blocks<br />
under <strong>the</strong> test structure.<br />
While processing <strong>the</strong> experimental results, it was noticed that no beam-to-column<br />
joint reached 35 mrad <strong>of</strong> plastic rotation. In Figure 4.58 <strong>the</strong> maximum rotations <strong>of</strong><br />
<strong>the</strong> joints are shown.<br />
+19.9 mrad<br />
-3.9 mrad<br />
+18.8 mrad<br />
-4.5 mrad<br />
166<br />
+30.2 mrad<br />
-9.8 mrad<br />
+10.3 mrad<br />
-5.9 mrad<br />
+30.4 mrad<br />
-8.4 mrad<br />
+11.6 mrad<br />
-3.9 mrad<br />
+21.5 mrad<br />
-23.2 mrad<br />
-0.7 mrad<br />
-6.6 mrad<br />
+22.1 mrad<br />
-22.1 mrad<br />
-4.3 mrad<br />
-4.3 mrad<br />
+22.2 mrad<br />
-16.6 mrad<br />
+26.4 mrad<br />
-17.8 mrad<br />
+28.7 mrad<br />
-16.6 mrad<br />
+30.1 mrad<br />
-14.9 mrad<br />
+6.5 mrad<br />
-0.0 mrad<br />
+3.7 mrad<br />
+2.9 mrad<br />
+20.9 mrad<br />
-18.3 mrad<br />
+5.4 mrad<br />
-9.9 mrad<br />
+24.0 mrad<br />
-19.1 mrad<br />
+6.7 mrad<br />
-19.0 mrad<br />
+15.5 mrad<br />
-8.4 mrad<br />
+17.3 mrad<br />
-0.1 mrad<br />
A3 A2 A1<br />
Figure 4.58. Maximum values <strong>of</strong> rotation reached by <strong>the</strong> beam-to-column joints <strong>of</strong> <strong>the</strong><br />
exterior frame during <strong>the</strong> PsD test n°3<br />
O<strong>the</strong>r remarks can now be made:<br />
• <strong>the</strong> maximum rotations <strong>of</strong> <strong>the</strong> joints at <strong>the</strong> first <strong>and</strong> second levels are quite <strong>the</strong><br />
same;<br />
• <strong>the</strong> joints on <strong>the</strong> span 1-2 <strong>of</strong> <strong>the</strong> interior frame rotated more than <strong>the</strong> exterior<br />
ones, thanks to a <strong>high</strong>er contribute <strong>of</strong> <strong>the</strong> web panels;<br />
II<br />
I