4. SEISMIC RESPONSE OF PARTIAL-STRENGTH COMPOSITE JOINTS<br />

3 (2001), in frame web panels <strong>of</strong> beam-to-column connections <strong>the</strong> following<br />

assessment is permitted:<br />

where<br />

V<br />

V<br />

wp, Ed<br />

wp, Rd<br />

≤ 1,0<br />

( 4.21 )<br />

Vwp,Ed is <strong>the</strong> design shear force in <strong>the</strong> web panel due to <strong>the</strong> action effects,<br />

taking into account <strong>the</strong> plastic resistance <strong>of</strong> <strong>the</strong> adjacent dissipative zones in<br />

beams or connections;<br />

Vwp,Rd is <strong>the</strong> shear resistance <strong>of</strong> <strong>the</strong> web panel according to J 3.5.1 <strong>of</strong> Annex C<br />

<strong>of</strong> <strong>the</strong> Eurocode 3. It is not required to take into account <strong>the</strong> effects <strong>of</strong> <strong>the</strong><br />

stresses <strong>of</strong> axial force <strong>and</strong> bending moment on <strong>the</strong> plastic resistance in shear.<br />

The shear resistance <strong>of</strong> <strong>the</strong> columns, in dissipative zones, should be<br />

determined on <strong>the</strong> basis <strong>of</strong> <strong>the</strong> structural steel section alone, unless special<br />

details are provided to mobilize <strong>the</strong> shear resistance <strong>of</strong> <strong>the</strong> concrete<br />

encasement.<br />

A possible system <strong>of</strong> internal actions that <strong>the</strong> panel zone <strong>of</strong> an interior beam-to-<br />

column connection may have to withst<strong>and</strong> is shown in Figure 4.13. Under this<br />

system <strong>of</strong> forces, shear deformation <strong>of</strong> <strong>the</strong> web panel zone occurs. A key<br />

simplification in this analysis is that <strong>the</strong> beam moments are replaced by an<br />

equivalent couple, with <strong>the</strong> forces acting at mid-depth <strong>of</strong> <strong>the</strong> beam flanges.<br />

Figure 4.13. Internal actions <strong>of</strong> an interior beam-to-column joint<br />

Under <strong>the</strong> assumption, <strong>the</strong> effective shear force in <strong>the</strong> web panel Vwp,Ed <strong>of</strong> an<br />

interior column at <strong>the</strong> structure collapse in <strong>the</strong> <strong>seismic</strong> design situation can be<br />

calculated as follows:<br />