<strong>EEC</strong> INTF - 2nd HSMS Port for APC Connection<br />

• Generic Approach<br />

– <strong>Lam</strong> equipment software acts as a server and passively listen to the<br />

2nd HSMS port<br />

– APC software has to connect to this port actively to establish a<br />

communication link<br />

– Data Sampling Plan(DSP) is created and activated in <strong>Lam</strong> CTC<br />

software<br />

– APC software can enable event report for wafer and recipe process<br />

activities<br />

– APC software can enable time trace data sending<br />

– Time trace data will be sent to 2nd HSMS port in real time(1 second)<br />

whenever data become available<br />

– CPU time clock can be synchronized through Date/Time request<br />

service<br />

– Messaging protocol<br />

10/15/2002 12:58 PM j:\stndpres\template\IntST.ppt - 11