ENGLISH<br />

BASICS<br />

2.1.3 Types of Construction<br />

The design of water pumps may vary<br />

widely and hence also their appearance.<br />

The construction of the housing<br />

and the type of drive are the<br />

most conspicuous diff erentiating<br />

features:<br />

Type of Drive<br />

The water pump is driven by the<br />

engine through a belt . This is either<br />

achieved through the timing belt of<br />

the camshaft control or through the<br />

Timing belt drive V-belt drive<br />

Housing Design<br />

Water pumps may be of open or<br />

clo sed design.<br />

In the case of open pumps, the<br />

engine possesses a fl ange-mounting<br />

V-belt and/or poly-rib belt from the<br />

crankshaft. If the pulley is not part<br />

of the pump, it has to be bolted to<br />

the fl ange of the driving shaft.<br />

face to which the pump is fastened<br />

and sealed by means of a sealing<br />

ring or a fl at gasket. The mating piece<br />

of the pump housing is part of the<br />

Pump with mounting fl ange Pump with housing<br />

24<br />

Pump without pulley<br />

engine. Closed pumps in contrast<br />

constitute a complete assembly: a<br />

counterpart, a plate or a cover will<br />

close the pump housing and seal it.