6.5.6.10 Tear test<br />

6.5.6.10.1 Applicability<br />

For all types of flexible IBCs, as a design type test.<br />

6.5.6.10.2 Preparation of the IBC for test<br />

The IBC shall be filled to not less than 95% of its capacity and to its maximum permissible<br />

gross mass, the contents being evenly distributed.<br />

6.5.6.10.3 Method of testing<br />

Once the IBC is placed on the ground, a 100 mm knife score, completely penetrating the<br />

wall of a wide face, is made at a 45° angle to the principal axis of the IBC, halfway between the bottom<br />

surface and the top level of the contents. The IBC shall then be subjected to a uniformly distributed<br />

superimposed load equivalent to twice the maximum permissible gross mass. The load shall be applied for at<br />

least five minutes. An IBC which is designed to be lifted from the top or the side shall then, after removal of<br />

the superimposed load, be lifted clear of the floor and maintained in that position for a period of five<br />

minutes.<br />

6.5.6.10.4 Criterion for passing the test<br />

6.5.6.11 Topple test<br />

6.5.6.11.1 Applicability<br />

The cut shall not propagate more than 25% of its original length.<br />

For all types of flexible IBCs, as a design type test.<br />

6.5.6.11.2 Preparation of the IBC for test<br />

The IBC shall be filled to not less than 95% of its capacity and to its maximum permissible<br />

gross mass, the contents being evenly distributed.<br />

6.5.6.11.3 Method of testing<br />

The IBC shall be caused to topple on to any part of its top on to a rigid, non-resilient,<br />

smooth, flat and horizontal surface.<br />

6.5.6.11.4 Topple height<br />

6.5.6.11.5 Criterion for passing the test<br />

Copyright@United Nations, 2011. All rights reserved.<br />

Packing group I Packing group II Packing group III<br />

1.8 m 1.2 m 0.8 m<br />

No loss of contents. A slight discharge, e.g. from closures or stitch holes, upon impact shall<br />