T50 PORTABLE TANK INSTRUCTION (cont'd) T50<br />

This portable tank instruction applies to non-refrigerated liquefied gases and chemicals under pressure (UN Nos.<br />

3500, 3501, 3502, 3503, 3504 and 3505).The general provisions of section 4.2.2 and the requirements of section<br />

6.7.3 shall be met.<br />

UN<br />

No<br />

Non-refrigerated liquefied gases<br />

Max. allowable<br />

working pressure<br />

(bar)<br />

Small; Bare;<br />

Sunshield; Insulated;<br />

respectively a<br />

3500 Chemical under pressure, n.o.s. See MAWP definition<br />

in 6.7.3.1<br />

3501 Chemical under pressure,<br />

flammable, n.o.s.<br />

3502<br />

Chemical under pressure, toxic,<br />

n.o.s.<br />

3503<br />

Chemical under pressure,<br />

corrosive, n.o.s.<br />

3504<br />

Chemical under pressure,<br />

flammable, toxic, n.o.s.<br />

3505<br />

Chemical under pressure,<br />

flammable, corrosive, n.o.s.<br />

Copyright@United Nations, 2011. All rights reserved.<br />

See MAWP definition<br />

in 6.7.3.1<br />

See MAWP definition<br />

in 6.7.3.1<br />

See MAWP definition<br />

in 6.7.3.1<br />

See MAWP definition<br />

in 6.7.3.1<br />

See MAWP definition<br />

in 6.7.3.1<br />

- 122 -<br />

Openings<br />

below liquid<br />

level<br />

Pressure-relief<br />

requirements b<br />

(see 6.7.3.7)<br />

Maximum<br />

filling ratio<br />

Allowed See 6.7.3.7.3 TP4 c<br />

Allowed See 6.7.3.7.3 TP4 c<br />

Allowed See 6.7.3.7.3 TP4 c<br />

Allowed See 6.7.3.7.3 TP4 c<br />

Allowed See 6.7.3.7.3 TP4 c<br />

Allowed See 6.7.3.7.3 TP4 c<br />

a<br />

“Small” means tanks having a shell with a diameter of 1.5 metres or less; “Bare” means tanks having a shell<br />

with a diameter of more than 1.5 metres without insulation or sun shield (see 6.7.3.2.12); “Sunshield” means<br />

tanks having a shell with a diameter of more than 1.5 metres with sun shield (see 6.7.3.2.12); “Insulated”<br />

means tanks having a shell with a diameter of more than 1.5 metres with insulation (see 6.7.3.2.12); (see<br />

definition of “Design reference temperature” in 6.7.3.1).<br />

b<br />

The word “Normal” in the pressure relief requirements column indicates that a frangible disc as specified in<br />

6.7.3.7.3 is not required.<br />

c<br />

For UN Nos. 3500, 3501, 3502, 3503, 3504 and 3505, the degree of filling shall be considered instead of the<br />

maximum filling ratio.<br />

T75 PORTABLE TANK INSTRUCTION T75<br />

This portable tank instruction applies to refrigerated liquefied gases. The general provisions of<br />

section 4.2.3 and the requirements of section 6.7.4 shall be met.