04.06.2013 Views

Corrigendum - REACH24H Consulting Group

Corrigendum - REACH24H Consulting Group

Corrigendum - REACH24H Consulting Group

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Copyright@United Nations, 2011. All rights reserved.<br />

IBC520 PACKING INSTRUCTION (cont'd) IBC520<br />

UN No. Organic peroxide Type of<br />

IBC<br />

3119 ORGANIC PEROXIDE, TYPE F, LIQUID,<br />

(cont'd) TEMPERATURE CONTROLLED (cont'd)<br />

tert-Butyl peroxypivalate, not more than 27% in diluent<br />

type B<br />

Cumyl peroxyneodecanoate, not more than 52%, stable<br />

dispersion, in water<br />

Di-(4-tert-butylcyclohexyl) peroxydicarbonate, not more<br />

than 42%, stable dispersion, in water<br />

Dicetyl peroxydicarbonate, not more than 42%, stable<br />

dispersion, in water<br />

Dicyclohexylperoxydicarbonate, not more than 42% as a<br />

stable dispersion, in water<br />

Di-(2-ethylhexyl) peroxydicarbonate, not more than 62%,<br />

stable dispersion, in water<br />

Diisobutyryl peroxide, not more than 28% as a stable<br />

dispersion in water<br />

Diisobutyryl peroxide, not more than 42% as a stable<br />

dispersion in water<br />

Dimyristyl peroxydicarbonate, not more than 42%, stable<br />

dispersion, in water<br />

Di-(2-neodecanoylperoxyisopropyl)benzene, not more than<br />

42%, stable dispersion, in water<br />

Di-(3,5,5-trimethylhexanoyl) peroxide, not more than 52%<br />

in diluent type A<br />

Di-(3,5,5-trimethylhexanoyl) peroxide, not more than 52%,<br />

stable dispersion, in water<br />

3-Hydroxy-1,1-dimethylbutyl peroxyneodecanoate, not<br />

more than 52%, stable dispersion, in water<br />

1,1,3,3-Tetramethylbutyl peroxyneodecanoate, not more<br />

than 52%, stable dispersion, in water<br />

3120 ORGANIC PEROXIDE, TYPE F, SOLID,<br />

TEMPERATURE CONTROLLED<br />

- 86 -<br />

31HA1<br />

31A<br />

Maximum<br />

quantity<br />

(litres)<br />

1 000<br />

1 250<br />

Control<br />

temperature<br />

+10 °C<br />

+10 °C<br />

Emergency<br />

temperature<br />

+15 °C<br />

+15 °C<br />

31A 1 250 - 15 °C - 5 °C<br />

31HA1 1 000 +30 °C +35 °C<br />

31HA1 1 000 +30 °C +35 °C<br />

31A 1 250 +10 °C +15 °C<br />

31A 1 250 -20 °C -10 °C<br />

31HA1<br />

31A<br />

31HA1<br />

31A<br />

1 000<br />

1 250<br />

1 000<br />

1 250<br />

-20 ºC<br />

-20 ºC<br />

-25 ºC<br />

-25 ºC<br />

-10 ºC<br />

-10 ºC<br />

-15 ºC<br />

-15 ºC<br />

31HA1 1 000 +15 °C +20 °C<br />

31A 1 250 -15 °C -5 °C<br />

31HA1<br />

31A<br />

1 000<br />

1 250<br />

+10 °C<br />

+10 °C<br />

+15 °C<br />

+15 °C<br />

31A 1 250 +10 °C +15 °C<br />

31A 1 250 -15 °C -5 °C<br />

31A<br />

31HA1<br />

1 250<br />

1 000<br />

-5 °C<br />

-5 °C<br />

+5 °C<br />

+5 °C<br />

Additional requirements:<br />

1. IBCs shall be provided with a device to allow venting during transport. The inlet to the pressure-relief device<br />

shall be sited in the vapour space of the IBC under maximum filling conditions during transport.<br />

2. To prevent explosive rupture of metal IBCs or composite IBCs with complete metal casing, the emergencyrelief<br />

devices shall be designed to vent all the decomposition products and vapours evolved during selfaccelerating<br />

decomposition or during a period of not less than one hour of complete fire-engulfment as<br />

calculated by the formula in 4.2.1.13.8. The control and emergency temperatures specified in this packing<br />

instruction are based on a non-insulated IBC. When consigning an organic peroxide in an IBC in accordance<br />

with this instruction, it is the responsibility of the consignor to ensure that:<br />

(a) the pressure and emergency relief devices installed on the IBC are designed to take appropriate account<br />

of the self-accelerating decomposition of the organic peroxide and of fire-engulfment; and<br />

(b) when applicable, the control and emergency temperatures indicated are appropriate, taking into account<br />

the design (e.g. insulation) of the IBC to be used.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!