Calibrating, Printing and Proofing by the G7™ Method
Calibrating, Printing and Proofing by the G7™ Method
Calibrating, Printing and Proofing by the G7™ Method
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Calibrating</strong>, <strong>Printing</strong> <strong>and</strong> <strong>Proofing</strong> <strong>by</strong> <strong>the</strong> G7 <strong>Method</strong> Version 6, August 2006<br />
E.4 Determining 'natural' CtP curves<br />
To determine <strong>the</strong> 'natural' print curves of commercial CtP-based printing, <strong>the</strong> GRACoL technical<br />
committee analyzed multiple ISO-st<strong>and</strong>ard press runs made with a variety of plates imaged on uncalibrated<br />
CtP systems, set up to manufacturer specifications. The resulting curve shape was <strong>the</strong>n<br />
smoo<strong>the</strong>d <strong>by</strong> <strong>the</strong> following equation;<br />
Where<br />
For TV (dot%) = 0 - 100;<br />
NPDC ND = IF(SiCoY > 0, LOG10(100/SiCoY), 1000) ;<br />
SiCoY (cmy) = 100 - 95.7 * SiCoTV/100;<br />
SiCoY (k) = 100 - 98 * SiCoTV/100;<br />
SiCoTV = TV + SiCoTVI;<br />
SiCoTVI (cmy) = (((1 - 1/10^ SIN(TV/100)) / 0.8559448 - TV/100) * 2.744 - ((0.1<br />
- 1/10^ COS(TV/100)) / - 0.1882025 - TV/100) * 0.594) * 25.2;<br />
SiCoTVI (k) = (((1 - 1/10^ SIN(TV/100)) / 0.8559448 - TV/100) * 2.2295 - ((0.1<br />
- 1/10^ COS(TV/100)) / - 0.1882025 - TV/100) * 1.0395) * 20.1;<br />
While every press run is unique, we believe <strong>the</strong> G7 NPDC formula represents what an average press<br />
running to ISO 12647-2 specifications would produce with typical un-calibrated CtP plates, on high<br />
quality commercial stock.<br />
E.5 Relationship of NPDC to TVI<br />
When correlated back to TVI curves (an inexact process) <strong>the</strong> G7 NPDC curves lie between <strong>the</strong> old<br />
positive <strong>and</strong> negative curves in ISO 12647-2, but closer to positive than negative. To fur<strong>the</strong>r align<br />
GRACoL 7 with o<strong>the</strong>r interpretations of ISO 12647-2, such as FOGRA <strong>and</strong> ECI in Europe <strong>and</strong> SWOP in<br />
<strong>the</strong> USA, <strong>the</strong> G7 black curve was lightened in February 2006.<br />
REMEMBER: G7 NPDC curves are NOT an official ISO st<strong>and</strong>ard. O<strong>the</strong>r valid interpretations of ISO<br />
12647-2 may produce slightly different NPDC curves.<br />
49 Copyright © International Digital Enterprise Alliance, Inc. [IDEAlliance] (2006). All Rights Reserved.