Calibrating, Printing and Proofing by the G7™ Method
Calibrating, Printing and Proofing by the G7™ Method
Calibrating, Printing and Proofing by the G7™ Method
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Calibrating</strong>, <strong>Printing</strong> <strong>and</strong> <strong>Proofing</strong> <strong>by</strong> <strong>the</strong> G7 <strong>Method</strong> Version 6, August 2006<br />
An offset press before G7 calibration (left) <strong>and</strong> after (right) showing NPDC calibration<br />
9.5 Verify gray balance <strong>and</strong> o<strong>the</strong>r parameters<br />
Check that o<strong>the</strong>r parameters like gray balance, cross-sheet evenness, etc., are still in spec, <strong>the</strong>n run a<br />
‘live sample’ of at least 1000 sheets at high speed <strong>and</strong> check that metrics are still good at <strong>the</strong> end of this<br />
speed run.<br />
9.6 Select samples<br />
Select a sampling of two or more good sheets from <strong>the</strong> live sample run <strong>and</strong> allow <strong>the</strong>m to dry naturally.<br />
If possible, make two or more separate press runs under similar conditions <strong>and</strong> select <strong>the</strong> best sheets<br />
from each run for subsequent averaging.<br />
9.7 Measure characterization data<br />
Measure characterization data from each of <strong>the</strong> selected sheets with a spectrophotometer, <strong>the</strong>n build an<br />
ICC press profile from <strong>the</strong> averaged data. If possible, save <strong>the</strong> original measurement data in spectral<br />
format ra<strong>the</strong>r than CIELab(D50). With suitable software <strong>and</strong> spectral data measured from a specific light<br />
source, spectral characterization data can yield an improved ICC profile that reduces <strong>the</strong> metameric<br />
problems caused <strong>by</strong> non-st<strong>and</strong>ard viewing conditions, or variations between st<strong>and</strong>ard light sources.<br />
9.8 Realistic expectations<br />
Remember that <strong>the</strong> act of characterizing a device is far more significant than any normal print run. The<br />
printed sheet from which <strong>the</strong> characterization data will be measured must be as 'perfect' as possible, in<br />
all visual terms, including solid colors, gray balance, NPDC <strong>and</strong> trapping, <strong>and</strong> <strong>the</strong>se characteristics<br />
should be as even as possible across <strong>the</strong> whole sheet, or at least <strong>the</strong> area of <strong>the</strong> characterization target.<br />
Offset printing is much harder to control consistently <strong>and</strong> evenly than a typical proofing system. Even<br />
<strong>the</strong> best press operated <strong>by</strong> <strong>the</strong> most experienced workers under ideal conditions can vary considerably<br />
from run to run, due to small changes in materials, temperature, humidity, length of run, etc. The<br />
chances of a 'perfect' press sheet from any particular offset press run are very small.<br />
If gray balance <strong>and</strong> o<strong>the</strong>r tolerances cannot be controlled precisely during <strong>the</strong> characterization test, aim<br />
for <strong>the</strong> best possible result but remember that <strong>the</strong> resulting characterization data will probably NOT<br />
represent <strong>the</strong> average performance of <strong>the</strong> device being characterized. In this case ei<strong>the</strong>r use <strong>the</strong><br />
st<strong>and</strong>ardized characterization data for that printing type - e.g. GRACoL 7 Characterization Data - or<br />
repeat <strong>the</strong> characterization process several times over a period of days or weeks <strong>and</strong> average <strong>the</strong><br />
results.<br />
31 Copyright © International Digital Enterprise Alliance, Inc. [IDEAlliance] (2006). All Rights Reserved.