Price List <strong>2012</strong> - Sanitaryware, Bathroom Furniture and Wellness<br />

Checklist for preparing to install whirlpool systems<br />

Dear Customer,<br />

Thank you for your interest in our product. The whirlpool system is delivered completely pre-assembled. In order to ensure the correct and safe installation of your whirlpool system, please<br />

note the following points:<br />

1. Connection to power supply<br />

o Connection to power supply Power supply with 230 V/50 Hz<br />

o Fuse Fuse max. 16 A.<br />

Residual-current devices (RCDs) with max. 30 mA rated release current<br />

o Potential equalisation line The system has to be connected to the potential equalisation in the bathroom in accordance with the applicable local rules.<br />

o Mains isolator The connector should be fitted with an all-pole mains switch, which is installed below the bath near the control box. When switched off, this<br />

switch should have a contact gap of at least 3 mm and meet safety requirements IPX5.<br />

o Connection The whirlpool system meets the requirements for devices in protection class I and is to be permanently connected to a distribution box via<br />

fixed cabling of at least 3 x 2.5 mm2.<br />

o Caution The installation of the electrical equipment and any necessary repairs may only be performed by a qualified electrical engineer. The applicable<br />

local regulations must be observed for the electrical installation.<br />

2. Outlet / water connection<br />

o Outlet The waste pipe should have a diameter of 40 - 50 mm and be prefitted near the installation site.<br />

o Water connection Please note the position of the taps. If the whirlpool system is fitted with a Multiplex Trio inlet fitting, the applicable national regulations for<br />

the water installation must be observed. A pipe interrupter is also required.<br />

3. Installation<br />

o Accessibility The technical parts of the whirlpool system must be accessible. To this end, a cover that can be dismantled is required. It should only be<br />

possible to remove this cover using tools.<br />

The position of the mains connection and of the other technical parts depends on the type of whirlpool selected and the bath model (see<br />

product pages).<br />

o Ventilation There has to be a ventilation grate or a ventilation opening; free cross-section min. 40 cm2.<br />

o Installation Please note that the installation height of a whirlpool is often greater than for a normal bath.<br />

The Villeroy & Boch Multibox was specially developed for these requirements and is available for most models.<br />

We recommend installing the whirlpool system against the tiled wall and on the tiled floor. Please take note of the work plan in order to<br />

prevent damage to the whirlpool system.<br />

4. Responsibilities of the customer<br />

o Condition of the floor Ensure that the condition of the floor is suitable to hold the weight of the whirlpool system and that the floor is resistant to moisture.<br />

o Transport Please check the route for transporting the whirlpool system into the bathroom for obstacles (stairs, doors) and check that there is sufficient<br />

room for manoeuvre, etc.<br />

o Ventilation The bathroom should have adequate ventilation (with the help of mechanical ventilation).<br />

o Noise reduction In order to prevent sound bridges, please take note of the following:<br />

-<br />

Direct contact with the building itself must be avoided, for example, with sufficiently large silicon joints or by using special soundproofing<br />

strips.<br />

- The prices are given in Euro excl. VAT.<br />

- All sizes are indicated in mm.<br />

- The installation site should be solid and low-vibration.<br />

- Any contact between the support structure and bath and/or system components must be avoided.<br />

- Tap fittings that are mounted directly onto the rim of the bath should be connected with flexible hoses<br />

Airborne sound is reduced by using insulating material (inside the wall and ceiling cavity) and by avoiding superfluous air outlets (below<br />

-<br />

the whirlpool)<br />

- Replace XX with colour code<br />

- For more information on the colours, see flip-out page and page 603.<br />

555<br />

WHIRLPOOL<br />

SYSTEMS