Revers – Osmose – System - tka.de
Revers – Osmose – System - tka.de
Revers – Osmose – System - tka.de
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Revers</strong>e osmosis system<br />
TKA RO 300 - DS<br />
Description of the system:<br />
Ready-to-connect reverse osmosis system for <strong>de</strong>mineralization of<br />
softened or hardness- stabilized tap water which complies with potable<br />
water regulations. It fulfils the following requirements:<br />
Colloid in<strong>de</strong>x: max. 3<br />
Salt content: max. 2,000 mg/Litre<br />
Free chlorine concentration: < 0.01 mg/Litre<br />
Manganese content: < 0.05 mg/Litre<br />
Iron content: < 0.05 mg/Litre<br />
Design of the system:<br />
RO 300 DS consists of a free-standing, compact, closed and dust-protective cabinet with inspection<br />
panel door, which contains all components including pre-treatment, a reverse osmosis module and<br />
digital microprocessor control. It can be upgra<strong>de</strong>d to a maximum of 1.100 l/h should water<br />
requirements increase. RO 300 DS is an i<strong>de</strong>al choice for supplying washing machines, autoclaves,<br />
sterilizers and automatic cleaners, air conditioners and cooling systems, industrial cleaning equipment<br />
and steam boilers, as well as sources of energy such as fuel cells etc..<br />
Construction of the system and filtration steps<br />
1 x Free-standing, compact, closed electronic cabinet with inspection panel door, <strong>de</strong>signed to hold<br />
all system components<br />
1 x 20“ Filter housing with activated carbon + 5 µm filter combi- cartridge for protection of<br />
downstream components against free chlorine and coarse particles<br />
1 x 20“ Filter housing with 3 µm particle filter cartridge for protection of downstream components<br />
from particles<br />
1 x Safety pressure switch protects against dry-running by switching off when the feed water<br />
pressure is too low<br />
1 x Pressure gauge for feed water and operating pressure for monitoring of the system and simple<br />
fault finding should a system fault occur<br />
1 x High pressure pump for generation of the operating pressure required to drive the permeation<br />
of water through the membrane<br />
1 x Spiral-wound membrane, together with pressure tube and all fittings required, for the removal<br />
of organic and inorganic contaminants, micro organisms, particles and colloids<br />
2 x Flow meters for display of concentrate and permeate flow<br />
2 x Regulating valves for adjustment of operating pressure and water conversion factor<br />
3 x Solenoid valves for the supply of feed water, quality rinse and permeate discard<br />
2 x Measuring cells for the <strong>de</strong>termination of feed water and permeate conductivities<br />
1 x Complete piping, materials PP, POM, PA and stainless steel<br />
1 x Digital microprocessor control for fully automatic monitoring and control of the reverse osmosis<br />
system<br />
TKA Wasseraufbereitungssysteme GmbH · Stockland 3 · D <strong>–</strong> 56412 Nie<strong>de</strong>relbert<br />
Phone +49 (0) 26 02 1 06 99 0 · Telefax +49 (0) 26 02 1 06 99 50<br />
E-mail: info@<strong>tka</strong>.<strong>de</strong> · www.<strong>tka</strong>.<strong>de</strong>
Characteristics and functions of the digital control:<br />
The digital microprocessor control inclu<strong>de</strong>s an illuminated, two-line, alpha-numeric LCD display with<br />
16 characters for the display of all operating functions and performance parameters. Major features<br />
are:<br />
• The plastic housing in which it is contained, protection type IP 65, has a plastic-foil keypad for<br />
start and flow of operations<br />
• High precision conductivity measurement in µS/cm for feed water and permeate, with limiting<br />
values for permeate or high purity water which can be set as required<br />
• High safety standard assured by an integrated main switch for voltage shut-off, a protective<br />
motor switch for safeguarding the pump, and micro fuses for all users and the control voltage<br />
of the electronics<br />
• Simple fault diagnosis/display, with fault display for feed water pressure, operating pressure<br />
gauge, and 230V/50Hz for display of faults by means of signal lamps and fault messages in<br />
the display<br />
• Cyclic, individually adjustable internal rinse for combating bacterial growth during standstill,<br />
cleaning and disinfection menu, automatic permeate discard, and return to the last operating<br />
mo<strong>de</strong> following a power cut<br />
• Possibility of connecting a water level controller, accessories and external comman<strong>de</strong>rs, as<br />
well as potential-free contacts and fault message displays<br />
• RS 232 interface with the possibility of connecting a serial printer with display of data and time<br />
via a real-time clock<br />
Technical specifications:<br />
Supply voltage: 380 V / 50 Hz<br />
Connected load: 1.60 kW<br />
Ambient temperature: 2 - 40° C<br />
Permeate performance (10° C): 300 Litres/h<br />
Operating pressure: max. 14 bar<br />
Feed water pressure: 2 - 6 bar<br />
Raw water conditioning: Softened tap water (0.1°dH)<br />
pH range: 4 - 11<br />
Colloid in<strong>de</strong>x: max. 3<br />
Membrane retention rate: 99 % Salts<br />
> 99 % Bacteria<br />
Water conversion factor (WCF): adjustable up to 75 %<br />
Permeate performance: 300 Litres at 10° C<br />
(after 3 years) 345 Litres at 15° C<br />
535 Litres at 25° C<br />
Make: TKA<br />
Type: DS Cabinet unit<br />
Dimensions in mm: W 800 x H 1800 x D 600<br />
Weight: 220 kg<br />
Article no.: 05.3300-DS<br />
TKA Wasseraufbereitungssysteme GmbH · Stockland 3 · D <strong>–</strong> 56412 Nie<strong>de</strong>relbert<br />
Phone +49 (0) 26 02 1 06 99 0 · Telefax +49 (0) 26 02 1 06 99 50<br />
E-mail: info@<strong>tka</strong>.<strong>de</strong> · www.<strong>tka</strong>.<strong>de</strong>