02.06.2013 Views

TMCM-351 CANopen Firmware Manual - Trinamic

TMCM-351 CANopen Firmware Manual - Trinamic

TMCM-351 CANopen Firmware Manual - Trinamic

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>TMCM</strong>-341/342/343/<strong>351</strong> <strong>CANopen</strong> <strong>Firmware</strong> <strong>Manual</strong> (V1.04 / 2011-AUG-01) 75<br />

8.1.12 Object 200C h, 220C h, and 240C h: Brake current feed<br />

This object configures how much current has to be fed into the brake to apply and to release it. 0<br />

means 0%, 255 means 100% of the maximum current (this depends on the module). In most cases it<br />

is needed to feed current into the brake to release it. The default configuration is made for this case.<br />

Setting both values to 0 disables the automatic brake control. This object is only writable in<br />

SWITCHED_ON_DISABLED state.<br />

Please note that on the three axis modules only 0 (brake output switched off) and 255 (brake<br />

output switched on) can be used. Set both values to zero if no brake is used. In such a case the<br />

brake output can be used as a normal digital output.<br />

OBJECT DESCRIPTION<br />

Index Name Object Code Data Type<br />

200C h (motor 0)<br />

220C h (motor 1)<br />

240C h (motor 2)<br />

Brake current feed ARRAY UNSIGNED8<br />

ENTRY DESCRIPTION<br />

Sub-Index Description Access PDO Mapping Value Range Default Value<br />

01 h Apply current rw no UNSIGNED8 0<br />

02 h Release current rw no UNSIGNED8 255<br />

8.1.13 Object 2085 h, 2285 h, and 2485 h: Ramp divisor<br />

Use this object to define the ramp divisor when internal units are selected for velocity and<br />

acceleration. Please see the TMCL manual and the hardware manual of the drive for more<br />

information about this value. This object can only be written in the SWITCHED_ON_DISABLE state (but<br />

is always readable).<br />

OBJECT DESCRIPTION<br />

Index Name Object Code Data Type<br />

2085 h (motor 0)<br />

2285 h (motor 1)<br />

2485 h (motor 2)<br />

Ramp divisor Variable UNSIGNED8<br />

ENTRY DESCRIPTION<br />

Sub-Index Access<br />

rw<br />

PDO Mapping Value Range Default Value<br />

00h not writable if user<br />

units are selected<br />

no 0… 13 7<br />

Copyright © 2011, TRINAMIC Motion Control GmbH & Co. KG