<strong>TMCM</strong>-341/342/343/<strong>351</strong> <strong>CANopen</strong> <strong>Firmware</strong> <strong>Manual</strong> (V1.04 / 2011-AUG-01) 73<br />

8.1.7 Object 2006 h, 2206 h, and 2406 h: Mixed decay threshold<br />

This object defines the behavior of the mixed decay feature of the drive. When it is set to the value<br />

-1, fast decay is always used. When it is set to a value between 0… 2047, fast decay will only be used<br />

when the internal velocity is higher or equal to that value. When set to 2048, fast decay will never be<br />

used.<br />

It is recommended to use -1. Only when stallGuard is to be used this value has to be set to 2048<br />

first.<br />

OBJECT DESCRIPTION<br />

Index Name Object Code Data Type<br />

2006 h (motor 0)<br />

2206 h (motor 1)<br />

2406 h (motor 2)<br />

Mixed decay threshold Variable UNSIGNED32<br />

ENTRY DESCRIPTION<br />

Sub-Index Access PDO Mapping Value Range Default Value<br />

00 h rw no -1… 2048 -1<br />

8.1.8 Object 2007 h, 2207 h, and 2407 h: Stall detection threshold<br />

This object defines if stallGuard is to be used. When set to 0, stallGuard will not be used. When<br />

set to 1… 7, the motor will be stopped and an emergency message will be generated if the stall value<br />

is the same or higher than the value set here. Switch off mixed decay (object 2006 h ) before using<br />

stallGuard.<br />

OBJECT DESCRIPTION<br />

Index Name Object Code Data Type<br />

2007 h (motor 0)<br />

2207 h (motor 1)<br />

2407 h (motor 2)<br />

Stall detection threshold Variable UNSIGNED8<br />

ENTRY DESCRIPTION<br />

Sub-Index Access PDO Mapping Value Range Default Value<br />

00 h rw no 0… 7 0<br />

8.1.9 Object 2009 h, 2209 h, and 2409 h: Fullstep threshold<br />

When the internal velocity gets higher than the value defined here the motor will be switched to<br />

fullstep operation. A value of 0 or 2048 turns off this feature. Normally only needed for getting more<br />

force in higher speeds.<br />

OBJECT DESCRIPTION<br />

Index Name Object Code Data Type<br />

2009 h (motor 0)<br />

2209 h (motor 1)<br />

2409 h (motor 2)<br />

Fullstep threshold Variable UNSIGNED8<br />

ENTRY DESCRIPTION<br />

Sub-Index Access PDO Mapping Value Range Default Value<br />

00 h ro no 0… 2048 0<br />