Number Axis Parameter Description<br />

130 minimum speed Should always be set 1 to ensure exact<br />

reaching of the target position. Do not<br />

change!<br />

138 ramp mode Automatically set when using ROR, ROL, MST<br />

and MVP.<br />

0: position mode. Steps are generated, when<br />

the parameters actual position and target<br />

position differ. Trapezoidal speed ramps are<br />

provided.<br />

2: velocity mode. The motor will run<br />

continuously and the speed will be changed<br />

with constant (maximum) acceleration, if the<br />

parameter target speed is changed.<br />

For special purposes, the soft mode (value 1)<br />

with exponential decrease of speed can be<br />

selected.<br />

140 microstep<br />

resolution<br />

141 ref. switch<br />

tolerance<br />

0 – full step*)<br />

1 – half step*)<br />

2 – 4 microsteps<br />

3 – 8 microsteps<br />

4 – 16 microsteps<br />

5 – 32 microsteps**)<br />

6 – 64 microsteps**)<br />

Note that modifying this parameter will affect<br />

the rotation speed in the same relation:<br />

*) The full-step setting and the half-step<br />

setting are not optimized for use without an<br />

adapted microstepping table. These settings<br />

just step through the microstep table in steps<br />

of 64 respectively 32. To get real full stepping<br />

use axis parameter 211 or load an adapted<br />

microstepping table.<br />

**) If the module is specified for 16<br />

microsteps only, switching to 32 or 64<br />

microsteps brings an enhancement in<br />

resolution and smoothness. The position<br />

counter will use the full resolution, but,<br />

however, the motor will resolve a maximum<br />

of 24 different microsteps only for the 32 or<br />

64 microstep units.<br />

For three-switch mode: a position range,<br />

where an additional switch (connected to the<br />

REFL input) won't cause motor stop. See<br />

section 9.1 for details.<br />

149 soft stop flag If cleared, the motor will stop immediately<br />

(disregarding motor limits), when the<br />

reference or limit switch is hit.<br />

153 ramp divisor The exponent of the scaling factor for the<br />

ramp generator- should be de/incremented<br />

carefully (in steps of one).<br />

154 pulse divisor The exponent of the scaling factor for the<br />

pulse (step) generator – should be<br />

de/incremented carefully (in steps of one).<br />