PD-109-57 V2 TMCL <strong>Firmware</strong> <strong>Manual</strong> (V1.00/2010-FEB-18) 70<br />
Number Axis Parameter Description<br />
130 minimum speed Should always be set 1 to ensure exact<br />
reaching of the target position. Do not<br />
change!<br />
138 ramp mode Automatically set when using ROR, ROL, MST<br />
and MVP.<br />
0: position mode. Steps are generated, when<br />
the parameters actual position and target<br />
position differ. Trapezoidal speed ramps are<br />
provided.<br />
2: velocity mode. The motor will run<br />
continuously and the speed will be changed<br />
with constant (maximum) acceleration, if the<br />
parameter target speed is changed.<br />
For special purposes, the soft mode (value 1)<br />
with exponential decrease of speed can be<br />
selected.<br />
140 microstep<br />
resolution<br />
141 ref. switch<br />
tolerance<br />
0 – full step*)<br />
1 – half step*)<br />
2 – 4 microsteps<br />
3 – 8 microsteps<br />
4 – 16 microsteps<br />
5 – 32 microsteps**)<br />
6 – 64 microsteps**)<br />
Note that modifying this parameter will affect<br />
the rotation speed in the same relation:<br />
*) The full-step setting and the half-step<br />
setting are not optimized for use without an<br />
adapted microstepping table. These settings<br />
just step through the microstep table in steps<br />
of 64 respectively 32. To get real full stepping<br />
use axis parameter 211 or load an adapted<br />
microstepping table.<br />
**) If the module is specified for 16<br />
microsteps only, switching to 32 or 64<br />
microsteps brings an enhancement in<br />
resolution and smoothness. The position<br />
counter will use the full resolution, but,<br />
however, the motor will resolve a maximum<br />
of 24 different microsteps only for the 32 or<br />
64 microstep units.<br />
For three-switch mode: a position range,<br />
where an additional switch (connected to the<br />
REFL input) won't cause motor stop. See<br />
section 9.1 for details.<br />
149 soft stop flag If cleared, the motor will stop immediately<br />
(disregarding motor limits), when the<br />
reference or limit switch is hit.<br />
153 ramp divisor The exponent of the scaling factor for the<br />
ramp generator- should be de/incremented<br />
carefully (in steps of one).<br />
154 pulse divisor The exponent of the scaling factor for the<br />
pulse (step) generator – should be<br />
de/incremented carefully (in steps of one).<br />
Copyright © 2010, TRINAMIC Motion Control GmbH & Co. KG