PD-109-57 V2 TMCL <strong>Firmware</strong> <strong>Manual</strong> (V1.00/2010-FEB-18) 67<br />

6.7.26 CCO (capture coordinate)<br />

The actual position of the axis is copied to the selected coordinate variable.<br />

Please note that the coordinate number 0 is always stored in RAM only. All others are also stored in<br />

the EEPROM.<br />

Internal function: The selected (24 bit) position values are written to the 20 by 3 bytes wide coordinate<br />

array.<br />

Related commands: SCO, GCO, MVP<br />

Mnemonic: CCO , <br />

Binary representation:<br />

INSTRUCTION NO. TYPE MOT/BANK VALUE<br />

32 <br />

(0…20)<br />

* Motor number is always 0 as only one motor is involved.<br />

Reply in direct mode:<br />

STATUS VALUE<br />

100 – OK (don't care)<br />

Example:<br />

Store current position of the axis to coordinate 3<br />

Mnemonic: CCO 3, 0<br />

Copyright © 2010, TRINAMIC Motion Control GmbH & Co. KG<br />

0*<br />

(don't care)<br />

Binary:<br />

Byte Index 0 1 2 3 4 5 6 7 8<br />

Function Target- Instruction Type Motor/ Operand Operand Operand Operand Checksum<br />

address Number<br />

Bank Byte3 Byte2 Byte1 Byte0<br />

Value (hex) $01 $20 $03 $00 $00 $00 $00 $00 $24