PD-109-57 V2 TMCL <strong>Firmware</strong> <strong>Manual</strong> (V1.00/2010-FEB-18) 60<br />

6.7.19 JA (jump always)<br />

Jump to a fixed address in the TMCL program memory. This command is intended for stand-alone<br />

operation only.<br />

The host address and the reply are only used to take the instruction to the TMCL program memory<br />

while the TMCL program loads down. This command cannot be used in direct mode.<br />

Internal function: The TMCL program counter is set to the passed value.<br />

Related commands: JC, WAIT, CSUB<br />

Mnemonic: JA <br />

Binary representation:<br />

INSTRUCTION NO. TYPE MOT/BANK VALUE<br />

22 (don't care) (don't care) <br />

Example: An infinite loop in TMCL<br />

Loop: MVP ABS, 0, 10000<br />

WAIT POS, 0, 0<br />

MVP ABS, 0, 0<br />

WAIT POS, 0, 0<br />

JA Loop //Jump to the label “Loop”<br />

Binary format of “JA Loop” assuming that the label “Loop” is at address 20:<br />

Byte Index 0 1 2 3 4 5 6 7 8<br />

Function Target- Instruction Type Motor/ Operand Operand Operand Operand Checksum<br />

address Number<br />

Bank Byte3 Byte2 Byte1 Byte0<br />

Value (hex) $01 $16 $00 $00 $00 $00 $00 $14 $2b<br />