PD-109-57 V2 TMCL <strong>Firmware</strong> <strong>Manual</strong> (V1.00/2010-FEB-18) 40<br />

6.7.8 RSAP (restore axis parameter)<br />

For all configuration-related axis parameters non-volatile memory locations are provided. By default, most<br />

parameters are automatically restored after power up (refer to axis parameter list in chapter 7). A single<br />

parameter that has been changed before can be reset by this instruction also.<br />

Internal function: The specified parameter is copied from the configuration EEPROM memory to its RAM<br />

location.<br />

Relate commands: SAP, STAP, GAP, and AAP<br />

Mnemonic: RSAP , <br />

Binary representation:<br />

INSTRUCTION NO. TYPE MOT/BANK VALUE<br />

8 * (don't care)<br />

* Motor number is always 0 as only one motor is involved.<br />

Reply structure in direct mode:<br />

STATUS VALUE<br />

100 – OK (don't care)<br />

List of parameters, which can be used for RSAP:<br />

Number Axis Parameter Description<br />

4 maximum<br />

positioning<br />

speed<br />

5 maximum<br />

acceleration<br />

6 absolute max.<br />

current<br />

Should not exceed the physically highest<br />

possible value. Adjust the pulse divisor (no.<br />

154), if the speed value is very low (