PD-109-57 V2 TMCL <strong>Firmware</strong> <strong>Manual</strong> (V1.00/2010-FEB-18) 35<br />

Number Axis Parameter Description Range [Unit]<br />

203 mixed decay<br />

threshold<br />

If the actual velocity is above this threshold,<br />

mixed decay will be used. This can also be set<br />

to -1 which turns on mixed decay<br />

permanently also in the rising part of the<br />

microstep wave. This can be used to fix<br />

microstep errors.<br />

204 freewheeling Time after which the power to the motor will<br />

be cut when its velocity has reached zero.<br />

205 stall detection<br />

threshold<br />

Stall detection threshold. Set it to 0 for no<br />

stall detection or to a value between 1 (low<br />

threshold) and 7 (high threshold). The motor<br />

will be stopped if the load value exceeds the<br />

stall detection threshold. Switch off mixed<br />

206<br />

decay to get usable results.<br />

actual load value Readout of the actual load value used for stall<br />

detection.<br />

208 Driver Error Flags<br />

of TMC249<br />

Bit<br />

7<br />

Name<br />

OT<br />

Function<br />

Overtemperature<br />

Remark<br />

1 = chip of due to<br />

211 fullstep<br />

threshold<br />

214 power down<br />

delay<br />

* Unit of acceleration:<br />

Copyright © 2010, TRINAMIC Motion Control GmbH & Co. KG<br />

6<br />

OTP<br />

W<br />

5 UV<br />

4 OCHS<br />

3 OLB<br />

2 OLA<br />

1 OCB<br />

0 OCA<br />

Temperature<br />

prewarning<br />

Driver<br />

undervoltage<br />

Overcurrent high<br />

side<br />

Open load<br />

bridge B<br />

Open load<br />

bridge A<br />

Overcurrent<br />

bridge B low<br />

side<br />

Overcurrent<br />

bridge A low<br />

side<br />

overtemperature<br />

1= prewarning<br />

temperature exceeded<br />

1 = undervoltage on VS<br />

3 PWM cycles with<br />

overcurrent within 63<br />

PWM cycles<br />

No PWM switch off for 14<br />

oscillator cycles<br />

No PWM switch off for 14<br />

oscillator cycles<br />

3 PWM cycles with<br />

overcurrent within 63<br />

PWM cycles<br />

3 PWM cycles with<br />

overcurrent within 63<br />

PWM cycles<br />

When exceeding this speed the driver will<br />

switch to real full step mode. To disable this<br />

feature set this parameter to zero or to a<br />

value greater than 2047.<br />

Setting a full step threshold allows higher<br />

motor torque of the motor at higher velocity.<br />

When experimenting with this in a given<br />

application, try to reduce the motor current in<br />

order to be able to reach a higher motor<br />

velocity!<br />

Standstill period before the current is changed<br />

down to standby current. The standard value<br />

is 200 (value equates 2000msec).<br />

0..2048<br />

or -1<br />

0…65535<br />

0 = never<br />

[msec]<br />

0…7<br />

0…7<br />

0… 7<br />

0..2048<br />

1… 65535<br />

[10msec]