Add-on devices<br />

20<br />

Redline<br />

Add-on devices<br />

Common add-on devices suitable for all MCB’s, RCD’s and Modular Switches<br />

Series<br />

Series G<br />

Series BP<br />

Series DM<br />

Diff-o-Click<br />

Aster<br />

Series Hti<br />

Auxiliary contact CA<br />

Description<br />

Auxiliary Contact H<br />

For monitoring the status of the protection device<br />

(Open/Close) independently if it has been<br />

actuated manually or automatically.<br />

Signal or Auxiliary Contact S/H<br />

For signalling the automatic tripping of the protection<br />

devices:<br />

- overload or short-circuit for MCB’s<br />

- earth leakage tripping for RCD’s<br />

Auxiliary contact CB<br />

Signal or Auxiliary Contact S/H + Auxiliary Contact H<br />

Two change-over contacts that include both functions<br />

as described above (S/H+H)<br />

Shunt trip Tele L<br />

Shunt Trip (Distance tripping by emission)<br />

For opening the device when it is fed locally or remotely<br />

Undervoltage release Tele U<br />

Undervoltage Release<br />

For opening the device when the voltage goes<br />

lower than a certain value<br />

Panel board switch PBS<br />

Panel Board Switch<br />

For opening the main device when the panel<br />

frame is removed<br />

Motor operator Tele MP<br />

Motor Operator<br />

Allows to switch on/off the devices from a distance<br />

Auxiliary contacts<br />

Auxiliary contact<br />

Signal contact S + test + reset<br />

Changeable auxiliary/signal contact<br />

Auxiliary contact and changeable auxiliary/signal contact<br />

Auxiliary contact and signal contact H + S + test + reset<br />

Shunt trip Tele L<br />

Shunt Trip (Distance tripping by emission)<br />

For opening the device when it is fed locally or remotely<br />

Voltage<br />

AC 24-60V -<br />

DC 24-48V<br />

AC110-415V -<br />

DC110-125V<br />

AC 240V<br />

AC/DC 12V<br />

AC/DC 24V<br />

AC/DC 48V<br />

AC 230V<br />

AC 110-415V<br />

DC 110-125V<br />

AC24-60V<br />

DC24-48V<br />

Modules<br />

0.5<br />

0.5<br />

0.5<br />

0.5<br />

0.5<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

0.5<br />

3<br />

0.5<br />

0.5<br />

0.5<br />

0.5<br />

0.5<br />

1<br />

1<br />

Function<br />

H<br />

S/H<br />

S/H<br />

SH/HH<br />

SH/HH<br />

TL<br />

TL<br />

TU<br />

TU<br />

TU<br />

TU<br />

PBS<br />

TM<br />

H<br />

S<br />

H/S<br />

H+H/S<br />

H+S<br />

TL<br />

TL<br />

Cat. No.<br />

CA H<br />

CA S/H<br />

CA S/H G*<br />

*golden contact<br />

CB SH/HH-R<br />

CB SH/HH-L<br />

TELE L-1<br />

TELE L-2<br />

TELE U-230<br />

TELE U-12<br />

TELE U-24<br />

TELE U-48<br />

PBS<br />

Tele MP<br />

Hti H<br />

Hti S<br />

Hti H/S<br />

Hti HH/HS<br />

Hti HSR<br />

TELE L 110<br />

TELE L 24<br />

Ref. No.<br />

672567<br />

672568<br />

672569<br />

672570<br />

672571<br />

672573<br />

672574<br />

672575<br />

672576<br />

672577<br />

672578<br />

672572<br />

672580<br />

671597<br />

671598<br />

671599<br />

671600<br />

671602<br />

624945<br />

624946