TMA SW version: 1.00 Build 24<br />
Rele<strong>as</strong>e Date: 2012-03-16<br />
Major highlights of this rele<strong>as</strong>e<br />
• First TMA rele<strong>as</strong>e for Windows OS (Windows XP & Windows 7)<br />
• Device Discovery for <strong>ThraneLink</strong> SLP supporting devices<br />
• SW Upload<br />
• Device Reboot<br />
• System Log Monitoring<br />
• Diagnostic Report retrieval<br />
• On-line context depend help<br />
Supported Devices<br />
The support devices and functions depends on the SW version currently available for each device type.<br />
The following devices have been verified during the TMA PRT:<br />
TT-Number Product<br />
BGAN<br />
SW<br />
Ver<br />
MIB Ver Discovery<br />
SW<br />
Upload<br />
Reboot Sys<br />
Log<br />
TT-3736/3738 BGAN-X BDU 1.14 201201030000Z Yes No No No No<br />
TT-<br />
3739A/3733A<br />
TT-3771<br />
TT-3027<br />
Diag<br />
Report<br />
BGAN-X BDU Lite 1.14 201201030000Z Yes No No No No<br />
BGAN Alarm<br />
Panel<br />
System 61x0<br />
Mini-C<br />
See note below<br />
1.01 201201030000Z Yes Yes Yes Yes No<br />
1.02 201201030000Z Yes Yes Yes Yes Yes<br />
TT-6006_C MessageTerminal 1.02 201201030000Z Yes Yes Yes No No<br />
TT-6194 TCU 1.02 201201030000Z Yes Yes Yes No No<br />
TT-6081A PSU 1.01 201201030000Z Yes Yes Yes No No<br />
TT-6101 Alarm Panel 1.01 201201030000Z Yes Yes Yes Yes No<br />
TT-6103 Multi Alarm Panel 1.01 201201030000Z Yes Yes Yes Yes No<br />
SAILOR Radios<br />
TT-6006_R MessageTerminal 1.02 201201030000Z Yes Yes Yes No No<br />
TT-62xx VHF Radio 2.10 201201030000Z Yes Yes Yes (Yes) No<br />
TT-63xx MF/HF Radio 1.05 201201030000Z Yes Yes Yes (Yes) No<br />
TT-6301 MF/HF CU 1.05 201201030000Z Yes Yes Yes (Yes) No
NOTE: Due to a known problem (Bug #45022) in the MT-6006 device discovery and<br />
management of the Mini-C (TT-3027) is not possible when the MT is present in a System 61x0.<br />
(To enable management of the Mini-C the MT must be powered off or disconnected from the<br />
CAN bus.)<br />
NOTE: BGAN-X BDU/AP (3771) have only been tested in a Sailor 250 system with 3771 connected.<br />
NOTE: Radio devices, with the above mentioned sw version, does support syslog. But until bug 45730<br />
have been solved, the function does NOT work properly. See Swatter for more details<br />
<strong>Software</strong> Upgrade of Devices using the TMA<br />
As support for ThraneLINK gradually h<strong>as</strong> been implemented in the different T&T devices the ability to<br />
support SW upload via the TMA depends on the device and the specific SW revision. During the TMA PRT<br />
SW upgrade h<strong>as</strong> been attempted for the different SW revisions <strong>as</strong> illustrated in the table below:<br />
TT-Number Product<br />
BGAN<br />
SW<br />
Ver<br />
SW<br />
Upload<br />
Comments<br />
TT-3736/3738 BGAN-X BDU 1.14 No ThraneLINK not yet supported in BGAN-X<br />
TT-<br />
3739A/3733A<br />
TT-3771<br />
BGAN-X BDU Lite 1.14 No ThraneLINK not yet supported in BGAN-X<br />
BGAN Alarm<br />
Panel<br />
System 61x0<br />
TT-3027 Mini-C<br />
TT-6006_C MessageTerminal<br />
TT-6194 TCU<br />
1.01 Yes<br />
1.00 Yes Via TCU. TCU SW must be at le<strong>as</strong>t rel. 1.01<br />
1.01 Yes Via TCU. TCU SW must be at le<strong>as</strong>t rel. 1.01<br />
1.02 Yes<br />
1.00 No<br />
1.01 Yes<br />
ThraneLINK not supported. Must be upgraded to rel.<br />
1.01 using USB<br />
1.02 Yes Note: Downgrade to rel. 1.01 not possible<br />
1.00 No<br />
1.01 Yes<br />
1.02 Yes<br />
TT-6081A PSU 1.01 Yes<br />
TT-6101 Alarm Panel<br />
1.00 Yes<br />
1.01 Yes<br />
TT-6103 Multi Alarm Panel 1.00 Yes<br />
ThraneLINK not supported. TTSDSUT can be used,<br />
to upgrade from 1.00 to 1.01
SAILOR Radios<br />
TT-6006_R MessageTerminal<br />
TT-62xx VHF Radio<br />
TT-63xx MF/HF Radio<br />
TT-6301 MF/HF CU<br />
1.01 Yes<br />
1.00 No<br />
1.01 Yes<br />
ThraneLINK not supported. Must be upgraded to rel.<br />
1.01 using USB<br />
1.02 Yes Note: Downgrade to rel. 1.01 not possible<br />
2.01 No<br />
2.10 Yes<br />
ThraneLINK not supported. Service Tool can be used<br />
to upgrade from 2.01 to 2.10<br />
1.04 No ThraneLINK not supported.<br />
1.05 Yes<br />
1.04 No ThraneLINK not supported.<br />
1.05 Yes