9. Heating connection<br />
Flue pipe connection left side:<br />
Flue pipe connection right side:<br />
29<br />
47,5*<br />
Heating flow 1“<br />
inlet /outlet temperature<br />
safety relief valve 1/2“<br />
4,8<br />
Heating return<br />
flow 1“<br />
65*<br />
10. Electrical connection<br />
power line<br />
53,5<br />
61<br />
* for an appliance height of 85 cm!<br />
EMERGENCY OFF<br />
connecting socket<br />
* … for an appliance height of 85 cm<br />
53,5<br />
46<br />
* for an appliance height of 85 cm!<br />
4,8<br />
65*<br />
Heating flow 1“<br />
Heating return<br />
flow 1“<br />
smoke/fire alarm<br />
inlet /outlet temperature<br />
safety relief valve 1/2“<br />
*<br />
29<br />
47,5*<br />
fig. 5<br />
StOvE PEllEtS MOdulE<br />
fig. 7<br />
fig. 6<br />
Output requirements for heating water<br />
Heat requirement during operation must exceed 1,6 kW. If the heat output falls<br />
below this value, the built-in safety devices will be activated and /or the appliance<br />
will be shut down.<br />
Return flow increase<br />
The return flow temperature must be at least 55 °C at the return flow connecting<br />
piece of the appliance (in the ideal case 60 °C), otherwise this will result in<br />
the building-up of soot and tar and as a consequence in corrosion.<br />
For dimensions and detailed information on the heating connection please refer to<br />
the installation and operation instructions of your stove.<br />
• When connecting the appliance by means of a plug to a socket, pay attention<br />
to the appropriate polarity (if necessary use a mains plug with<br />
an anti-twist protection) because the appliance must be connected in the<br />
proper phase!<br />
• An emergency power-off switch or an individual safety device is to be installed<br />
into the main distribution (for maintenance works, etc.<br />
• It is imperative that electrical connections regarding the appliance are to<br />
be carried out by a qualified professional in accordance with the applicable<br />
technical regulations, especially the VDE- and OVE-regulations. We do not<br />
accept liability for damages to the appliance as a result of inexpert connections<br />
and are subsequently excluded from warranty.<br />
• All electrical connecting cables leading from and to the appliance must not<br />
touch hot exterior surfaces of the appliance or of the chimney flue. The<br />
cables must not be laid over sharp edges.<br />
• The appliance has been exclusively designed to operate with an AC voltage<br />
of 230 V /50 Hz.<br />
• Voltage fluctuations ranging from –15 % up to +10 % are permissible.<br />
If possible the mains cable which is supplied with the appliance should be connected<br />
to the power line prior to the installation of the appliance!<br />
• The connection is carried out by means of a 3-pole mains cable (to be supplied<br />
with the appliance).<br />
• Do not use sockets with power plugs without anti-twist safeguard as the appliance<br />
is dependent on the phase!<br />
• It is imperative that you install a protective earth conductor!<br />
• A 5 x 20 2,5 A T glass tube safety fuse serves as main fuse. The fuse is installed<br />
at the front wall of the built-in cupboard (inside).<br />
• An emergency stop switch is to be installed by the owner (for maintenance<br />
works, etc.).<br />
We strongly recommend the installation of a smoke detector or fire warning device<br />
which interrupts the current supply of the appliance in case of an emergency! Objects<br />
which have been left inadvertently on the cooking surface are likely to catch fire<br />
in case of automatic starting-up of the pellet burner (e.g. with an automatic timing<br />
device).<br />
page 9