31. Terminal connection diagram<br />

Earthing<br />

Boiler pump blue<br />

brown<br />

black<br />

Auger motor Earthing<br />

white<br />

STB<br />

Bridge (P6)<br />

STB<br />

STB (P7)<br />

(Resetting safety Earthing<br />

temperature limiter)<br />

black<br />

Capacitor<br />

Capacitor<br />

Induced draught<br />

brown<br />

Earthing<br />

blue<br />

Ingnition<br />

Grate motor<br />

Damper motor<br />

Mains connection<br />

CAUTION:<br />

Observe polarity!<br />

blue<br />

brown<br />

Earthing<br />

brown<br />

(nb)<br />

white<br />

blue<br />

L<br />

N<br />

(nb)<br />

blue<br />

Earthing<br />

brown<br />

PE<br />

7<br />

6<br />

5<br />

PE<br />

4<br />

3<br />

2<br />

PE<br />

6<br />

5<br />

4<br />

3<br />

PE<br />

1<br />

10<br />

9<br />

PE<br />

7<br />

PE<br />

5<br />

4<br />

3<br />

2<br />

PE<br />

J10<br />

32. Operating panel language<br />

Language Position toggle switch<br />

German<br />

English<br />

Italian<br />

French<br />

ON<br />

ON<br />

ON<br />

ON<br />

1<br />

1<br />

1<br />

1<br />

2 3 4<br />

2 3 4<br />

2 3 4<br />

2 3 4<br />

J8<br />

J9<br />

N<br />

table 4<br />

PE L<br />

J7<br />

J6<br />

Control panel<br />

1<br />

2<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

Fuse<br />

Micro-fuse 5 x 20 mm / 2,5 A / T / Ceramic body<br />

J3<br />

J1<br />

J2<br />

J4<br />

J5<br />

green<br />

white<br />

red<br />

white<br />

red<br />

white<br />

S1<br />

S3<br />

red<br />

white<br />

white<br />

white<br />

S2<br />

S1<br />

bridge<br />

Flame sensor<br />

Oven/Exhaust gas sensor<br />

Plug-in sensor<br />

Contact change-over damper<br />

Boiler sensor<br />

Serial input /output<br />

(RS 232, Maintenance/Update)<br />

Dumping grate<br />

Dumping grate contact<br />

External release<br />

Upon delivery the language on the switch panel is selected according to the<br />

country to which the appliance is supplied. If necessary the language can be set<br />

by means of toggle switches on the back of the switch panel (table 3).<br />

page 25